Orange 18 AWG Primary Wire - 100'Pacer's marine wire is designed to handle the harshest marine environments. It is manufactured to meet and exceed the most stringent specifications. This 18 AWG marine wire is constructed in the USA to achieve the highest level of quality. Built from Type III class K tinned copper, this wire offers excellent flexibility. The tinned copper also resists corrosion adding to the life of the wire. What about the insulation? After the copper is tinned it is then insulated with a durable and flexible PVC jacket. The jacket makes this 18 AWG marine wire resistant to alkali, abrasion, acid, gas, oil, flame, and moisture. What standards and compliances does this wire meet? Pacer's marine wire exceeds the requirements and standards of UL, ABYC, and NMMA. Features:
Built for durability, flexibility, and longevity in the harshest marine environments
So flexible that you can tie it into a knot without compromising any of its qualities
Proprietary insulation ensures the highest level of protection available
Ease of installation and the longevity of its design have helped solidify this marine wire as the choice of boating professionals
Compliances:
UL Standard - 1426 BC-5W2
U.S.C.G - 33 CFR part 183
ABYC - E-11.14
Technical Specifications:
Conductor - Type III annealed finely stranded tinned copper ASTM B172 Class K
Insulation -20 °C to 105 °C flexible, color-coded PVC
Voltage Rating - 600-V
Resistant to - Acid, Alkali, Abrasion, Flame, Gasoline, Oil and Moisture
*Sold as an Individual Specifications:
Color: Orange
Gauge: 18 AWG
Length (Feet): 100'
Box Dimensions: 3"H x 5"W x 5"L WT: 1.25 lbs
UPC: 840248201049
Brochure (pdf)
Light Blue 16 AWG Primary Wire - 250' Pacer's marine wire is designed to handle the harshest marine environments. It is manufactured to meet and exceed the most stringent specifications. This 16 AWG marine wire is constructed in the USA to achieve the highest level of quality. Built from Type III class K tinned copper, this wire offers excellent flexibility. The tinned copper also resists corrosion adding to the life of the wire. What about the insulation? After the copper is tinned it is then insulated with a durable and flexible PVC jacket. The jacket makes this 16 AWG marine wire resistant to alkali, abrasion, acid, gas, oil, flame, and moisture. What standards and compliances does this wire meet? Pacer's marine wire exceeds the requirements and standards of UL, ABYC, and NMMA. Features:
Built for durability, flexibility, and longevity in the harshest marine environments
So flexible that you can tie it into a knot without compromising any of its qualities
Proprietary insulation ensures the highest level of protection available
Ease of installation and the longevity of its design have helped solidify this marine wire as the choice of boating professionals
Compliances:
UL Standard - 1426 BC-5W2
U.S.C.G - 33 CFR part 183
ABYC - E-11.14
Technical Specifications:
Conductor - Type III annealed finely stranded tinned copper ASTM B172 Class K
Insulation -20 °C to 105 °C flexible, color-coded PVC
Voltage Rating - 600-V
Resistant to - Acid, Alkali, Abrasion, Flame, Gasoline, Oil and Moisture
*Sold as an Individual Specifications:
Color: Light Blue
Gauge: 16 AWG
Length (Feet): 250'
Box Dimensions: 2"H x 6"W x 7"L WT: 4 lbs
UPC: 840248201544
Brochure (pdf)
Pink 16 AWG Primary Wire - 100' Pacer's marine wire is designed to handle the harshest marine environments. It is manufactured to meet and exceed the most stringent specifications. This 16 AWG marine wire is constructed in the USA to achieve the highest level of quality. Built from Type III class K tinned copper, this wire offers excellent flexibility. The tinned copper also resists corrosion adding to the life of the wire. What about the insulation? After the copper is tinned it is then insulated with a durable and flexible PVC jacket. The jacket makes this 16 AWG marine wire resistant to alkali, abrasion, acid, gas, oil, flame, and moisture. What standards and compliances does this wire meet? Pacer's marine wire exceeds the requirements and standards of UL, ABYC, and NMMA. Features:
Built for durability, flexibility, and longevity in the harshest marine environments
So flexible that you can tie it into a knot without compromising any of its qualities
Proprietary insulation ensures the highest level of protection available
Ease of installation and the longevity of its design have helped solidify this marine wire as the choice of boating professionals
Compliances:
UL Standard - 1426 BC-5W2
U.S.C.G - 33 CFR part 183
ABYC - E-11.14
Technical Specifications:
Conductor - Type III annealed finely stranded tinned copper ASTM B172 Class K
Insulation -20 °C to 105 °C flexible, color-coded PVC
Voltage Rating - 600-V
Resistant to - Acid, Alkali, Abrasion, Flame, Gasoline, Oil and Moisture
*Sold as an Individual Specifications:
Color: Pink
Gauge: 16 AWG
Length (Feet): 100'
Box Dimensions: 3"H x 5"W x 5"L WT: 1.75 lbs
UPC: 840248201612
Brochure (pdf)
Tank Level Monitor Sender InterfaceThe 600-TLM-SIF signal converter module is used to convert from 10-180 ohm, or 240-33 ohm tank sender outputs, to a 0-5V output. BEP equipment that uses a 0-5 volt signal input includes the DCSM DC/Systems Monitor, CZone Digital Switching/Monitoring, and the 600-TLM tank monitor.
A-Series ELCI Main Circuit Breaker - Double Pole 120V AC 30AFeatures:
Trips on short circuit, overload, or leakage to ground
Front panel mount—installed in a power distribution panel
Specifications:
Amperage: 30A
Color: White
Actuator Style: Toggle
Poles: 2
Ignition Protected: Yes
Max Voltage: 240VAC/120VAC per pole
Circuit Breaker Type: Magnetic Hydraulic - trip free
Interrupt Capacity: 5000A
Minimum Operating Temperature: -35 degrees C
Max Operating Temperature: 65 degrees C
Leakage Trip Amps: 30mA
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
Kill Switch & LanyardAdd safety to older boats easily. In an emergency, a quick pull on the lanyard stops the engine, preventing accidental runaway. Includes switch, lanyard, and disconnect clip. Contact engine manufacturer for specific installation instructions.Features:
Nominal voltage is 12V/24V DC
Rated for 10A at 12V DC
7" 16 AWG wire leads for terminals
IP65
Same as Cole Hersee part number M-597
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
5235ATO/ATC Fuse1A
Fast-acting type fuse ideal for electronic devices
Standard circuit protection device for automobiles and trucks
Tin-plated connector blades for corrosion resistance
Visible indication of blown condition
Sold in packages of 2
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Amperage: 1a
Fuse Type: ATO/ATC
Type: Fuses
Box Dimensions: 1"H x 3"W x 5"L WT: 0.1 lbs
UPC: 632085052355
5243ATO/ATC Fuse20A
Fast-acting type fuse ideal for electronic devices
Standard circuit protection device for automobiles and trucks
Tin-plated connector blades for corrosion resistance
Visible indication of blown condition
Sold in packages of 2
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Amperage: 20a
Fuse Type: ATO/ATC
Type: Fuses
Box Dimensions: 1"H x 3"W x 4"L WT: 0.1 lbs
UPC: 632085052430
14/2 AWG Duplex Cable - Red/Black - Sold By The Foot Ancor is the original Marine Grade® wire. This means that all of our wire and cable is built to withstand the harsh marine environment. Proprietary jacketing material is extremely UV and corrosion resistant. Individually tinned wire strands ensure optimal conductivity. Features:
Ultra flexible
Highly flexible color coded wire insulation
Stranded, tinned copper conductors
Compliances:
UL Standard - 1426
U.S.C.G - Title 46
ABYC
Technical Specifications:
Conductor - Type III
Insulation -40 °C to 105 °C flexible
Voltage Rating - 600-V
Resistant to - salt water, battery acid, oil, gasoline, heat, abrasion and ultra-violet radiation
No. of Conductors - 2
Type of Cable - Duplex
*Sold by the Foot Specifications:
Color: Red/Black
Gauge: 14/2 AWG
Length (Feet): Sold By The Foot
Box Dimensions: 1"H x 1"W x 12"L WT: 0.1 lbs
Battery Switch Key Lock Replacement - RedReplacement Key Lock for Battery SwitchWARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
2710 Cover for DualBus 2702Specifications:
Length: 6-3/8"
Height: 7/8"
Width: 2-3/8"
Weight: 0.04lb
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
MultiPlus-II 24/3000 - 70-50 - 2x120V The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A).It also has all the features of the MultiGrid with built-in anti-islanding and an increasingly long list of country approvals.PowerAssistThe MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery.ESS: Energy Storage SystemsThe MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. Uninterrupted AC power (UPS function)In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.Remote Monitoring & ControlWhen coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto starting a backupgenerator and more…"Note: for a short period of time this product was called MultiGrid-II.Please contact your dealer for any returns, repairs or support issues related to this product. Quick Guide (pdf)Owner's Manual (pdf)Brochure (pdf)