175WR-4 Transducer Housing WrenchA single-handed wrench that holds the main thru-hull housing via the 'wrench flats' on the top of the housing to facilitate tightening of the hull nut. Use wrench 164WR-2 or 164WR-3 for the hull nut.For use with:
B164
B175
SS164
SS264
IMPORTANT: the design of the housing for these transducers changed slightly in June 2012. This wrench is for the newer design and has an internal width of 2-3/4". If you need a wrench for the older designs then use the 164WR-4 instead, with an internal width of 2-7/16". Specifications:
Type: Tools
Box Dimensions: 1"H x 5"W x 10"L WT: 0.6 lbs
75WR-4 Transducer Housing WrenchA single-handed wrench that holds the main thru-hull housing via the 'wrench flats' on the side of the housing to facilitate tightening of the hull nut. Use wrench 75WR-2 or 75WR-3 for the hull nut.For use with:
B75
SS75
Specifications:
Type: Tools
Box Dimensions: 1"H x 5"W x 10"L WT: 0.6 lbs
60WR-4 Transducer Housing WrenchA single-handed wrench that holds the main thru-hull housing via the 'wrench flats' on the side of the housing to facilitate tightening of the hull nut.Use wrench 60WR-2 or 60WR-3 for the hull nut.For use with:
B60
SS60
Specifications:
Type: Tools
Box Dimensions: 1"H x 4"W x 9"L WT: 0.5 lbs
117WR-4 Transducer Housing WrenchA single-handed wrench that holds the main thru-hull housing via the 'wrench flats' on the side of the housing to facilitate tightening of the hull nut. For 2" bronze and stainless steel housings (P617V, B617V, SS617V).Use wrench 117WR-2 or 117WR-3 for the hull nut.*Note that this wrench will not fit on the CA500 camera housing. Specifications:
Type: Tools
Box Dimensions: 1"H x 3"W x 8"L WT: 0.45 lbs
164WR-2 Transducer Hull Nut WrenchA single-handed wrench to tighten the hull nut on B164, SS164 and SS264 housings.You can use wrench 164WR-4 to brace the housing when using this wrench.For use with:
B164
SS164
SS264
Specifications:
Type: Tools
Box Dimensions: 1"H x 6"W x 11"L WT: 0.85 lbs
75WR-2 Transducer Hull Nut WrenchA single-handed wrench to tighten the hull nut on bronze and stainless steel housings. You can use wrench 75WR-4 to brace the housing when using this wrench.For use with:
B75
SS75
Specifications:
Type: Tools
Box Dimensions: 1"H x 5"W x 9"L WT: 0.65 lbs
60WR-2 Transducer Hull Nut WrenchA single-handed wrench to tighten the hull nut on 2" bronze and stainless steel housings. You can use wrench 60WR-4 to brace the housing when using this wrench.For use with:
B60
SS60
Specifications:
Type: Tools
Box Dimensions: 1"H x 5"W x 9"L WT: 0.55 lbs
117WR-2 Transducer Hull Nut WrenchA single-handed wrench to tighten the hull nut on 2" bronze and stainless steel housings.You can use wrench 117WR-4 to brace the housing when using this wrench.For use with:
B117
B150
B744V
B744VL
B765C
SS555
Specifications:
Type: Tools
Box Dimensions: 1"H x 4"W x 9"L WT: 0.6 lbs
NMEA 0183 to NMEA2000 Gateway with PC Interface - USB ConnectionShare engine information on the NMEA 2000 bus.The Actisense EMU-1 is a specialized analogue to NMEA 2000 Gateway which converts data from analogue engine gauges/senders into NMEA 2000 data. The EMU-1 enables the sharing of engine data throughout the NMEA 2000 bus. It digitizes analogue engine sensors, enabling NMEA 2000 display devices to monitor the connected engine(s) on a vessel.The EMU-1 can monitor vital engine parameters such as temperature, pressure RPM and fluid levels from up to two engines.The EMU-1 has a PC-based configuration tool that allows the settings inside the EMU-1 to be changed to best suit the engine it is working with, making it a flexible solution for many engine makes and models.An Actisense PC to NMEA 2000 Gateway (NGX-1/NGT-1) is required to configure the EMU-1.The NGX-1 or NGT-1 must be used to update the firmware, connect the Toolkit and display data on a PC for diagnostic and information purposes, using NMEA Reader. Please visit the NGX-1 page and/or NGT-1 page for product details.Features:
Enables analogue signals to be converted to NMEA 2000 messages
Convert signals from up to two engines (that share a common ground) with a single EMU-1
6 gauge / parameter inputs
4 alarm inputs
2 additional auxiliary inputs
2 Tacho inputs
Customized IP65 case
Diagnostic LED’s
Wide power compatibility of 9 to 35VDC
No need to change an existing engine
Easy installation
Easy to configure to suit the connected engine
Connect signals from fluid level gauges (that share a common ground with the engine) to NMEA 2000®
Optional DIN rail mounting kit available
Total engine hours are logged by the monitoring of engine Tach (RPM) input
Technical Specifications:Power Supply
Supply Voltage - 9 to 35VDC
Supply Current - Typically < 25mA @ 12VDC
Supply Protection - Continuous reverse polarity protection and load dump protection (meets SAE J1113)
Supply Connector - Pluggable 2-way screw terminal, 3.5mm pitch
Supply Voltage (NMEA 2000 Port) - 9 to 29VDC
Supply Current (NMEA 2000 Port) - < 20mA @ 12VDC from NMEA 2000 bus
Load Equivalent Number (LEN) - 1
Supply Protection (NMEA 2000 Port) - Continuous reverse polarity protection and overvoltage protection to 40V
NMEA 2000 Port – In/Out
Compatibility - Fully NMEA 2000 certified
Galvanic Isolation - 2500V input to ground, 1500V output to ground using ISO-Drive
Speed / Baud Rate - 250kbps
NMEA 2000 Connector - M12 male (A coded) connector
Gauge Inputs
Voltage Range - 0 to 35VDC
Input Impedance - > 50kΩ
Sender Feed - 0, 4 or 18mA
Accuracy - <= 2%
Input Connector - Pluggable 6-way screw terminal, 3.5mm pitch
Input Protection - Overvoltage protection to ±40V
Alarm Inputs
Voltage Range - 0 to 37VDC
Input Impedance - > 50kΩ
Threshold Voltage - Configurable, default is 5V
Alarm Polarity - Configurable, default is alarm on low input
Accuracy - <= 2%
Input Connector - Pluggable 4-way screw terminal, 3.5mm pitch
Input Protection - Overvoltage protection to ±40V
Tacho Inputs
Voltage Range - ±3 to ±60V
Input Impedance - > 100kΩ to ground
Input Pulse Range - 4 to 50,000Hz
Accuracy - <= 1%
Sender Compatibility - Ignition coil, alternator (“W”, “R” or “AC”) terminal, hall effect, VR or inductive sender
Threshold - Automatically adjusts to signal level
Input Connector - Pluggable 4-way screw terminal, 3.5mm pitch
Input Protection - Can withstand an ignition pulse to ±500V
Engine LogEngine Hours - 2 separate engine hour logs internally connected to the tacho Inputs. Hours are logged when RPM is present, stored in non-volatile memoryMechanical
Housing Material - Polycarbonate
Protective Lid Material - Polycarbonate
Sealing Materials - Expanded silicone foam gasket, closed cell polyurethane splash guard and ePTFE waterproof vent
Dimensions - 127mm (L) x 112mm (W) x 48mm (H)
Weight - 250g
Mounting - 4 x 3.5mm lugs to allow panel mount with self tapping s/s screws (included), optional DIN Rail mount available on request
Approvals and Certifications
EMC - EN 60945 (sections 9 & 10)
Environmental Protection - IP66 (PCB housing)
Operating Temperature - -20°C to +55°C
Storage Temperature - -30°C to +70°C
Recommended Humidity - 0 – 93% RH
Guarantee - 3 years
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Specifications:
Cable Length (Feet): N/A
Data Interface: NMEA 2000
Box Dimensions: 3"H x 6"W x 9"L WT: 1 lbs
UPC: 5060998710331
Owner's Manual (pdf)Brochure (pdf)
Transom Mounting Bracket for P66 Transducer - 2004 & upThis product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Specifications:
Type: Mounting Brackets
Box Dimensions: 2"H x 3"W x 4"L WT: 0.2 lbs
UPC: 801769004656
0183 to N2K Gateway with PC Interface, ISO ConnectionIntelligent Gateway technology enables PC interfacing and NMEA data conversion…The NGX-1 is an intelligent multi-function gateway, combining the power of our two previous generation products (NGT-1 and NGW-1) into one, cost effective, flexible product.Configure the NGX-1 to operate as an NMEA 2000 <–> PC interface, or as a bi-directional NMEA 0183 <–> NMEA 2000 conversion gateway.Features:
View all NMEA 2000 network data on Actisense NMEA Reader. The device supports every available PGN in the NMEA 2000 standard.
View converted NMEA 0183 data on Actisense NMEA Reader. The device sports the largest conversion library of any gateway.
Easily interface with a wide range of PC applications via the NGX-1, such as TimeZero (NMEA 2000) and OpenCPN (NMEA 0183).
Configure the Actisense EMU-1, NGW-1 and NGX-1 via Actisense Toolkit using an NGX-1.
Connect legacy NMEA 0183 instruments together with new NMEA 2000 networks, greatly reducing upgrade costs.
Vital NMEA 2000 diagnostic tool
OPTO-isolated input and ISO-Drive™ output for safely interfacing with RS232 or RS422
Up to 230,400 baud data transfer rate
Advanced configuration using Actisense Toolkit allows Tx / Rx lists and Tx rates to be set
Supports Fast Heading at 10Hz
Multiple diagnostic LEDs
Allows all major PC Chartplotter applications to interface with the NMEA 2000 bus
Provides a rule-enforcing firewall between the PC and the NMEA 2000 bus
Powerful diagnosis of the NMEA 2000 network using the FREE NMEA Reader software provided
Configure and flash-update Actisense products on the bus
Upgrade NMEA 0183 equipment to NMEA 2000
Allow NMEA 0183 devices to receive vital NMEA 2000 data
Use the NMEA 2000 bus to multiplex several NMEA 0183 signals together
Reliable, renowned bi-directional conversion engine
Supports a wide range of conversions including AIS
Easily configurable using Actisense Toolkit
Technical SpecificationsPower Supply
Supply Voltage (NMEA 2000 Port) - 9 to 30V DC
Supply Current (NMEA 2000 Port) - 62mA @ 9V DC
Load Equivalent Number (LEN) - 2
NMEA 2000 Port
Speed / Baud Rate - 250kbps
Connectivity - M12 Male (A coded)
ISO Port
Compatibility - Full NMEA 0183, RS232 & RS422 compatibility. RS485 Listener compatible
Speed/Baud Rate - 4800 to 230400 Baud
Output Voltage Drive - >= 2.1V (differential) into 100Ω
Output Current Drive - 20mA max.
Output Protection - Short circuit and ESD
Input Voltage Tolerance - -15V to +15V continuous -35V to +35V short term (< 1 second)
Input Protection - Current limited and overdrive protection to 40VDC
Connectivity - 5mm stripped and tinned wire
Cable Length - 0.75m
Isolation
NMEA 2000 Port to ISO Port - Uses IsoDriveTM, Hi-Pot tested to 1000V
NMEA 2000 Port to USB Port - Galvanic Isolation, Hi-Pot tested to 1000V
Mechanical
Housing Material Body - Flame retardant Polycarbonate
Housing Material End Caps - Flame retardant PBT
Weight - 113g
Approvals and Certifications
NMEA 2000 - NMEA 2000 Certified
NMEA 0183 - Meets IEC 61162-1 & 61162-2 Requirements
RoHS and REACH - Compliant
Module Certification - KCC / BQB / IC / Wi-Fi / NCC / MIC / FCC DSS / FCC DTS / SRRC / CE, EN 60945:2002 Edition 4 (section 9.3), EN 301 489-1 V2.2.3, EN 301 489-17 V3.2.4
EMC - EN 300 328 V2.2.2 Radiated Spurious Emissions, FCC Part 15b, ICES-003 Iss 7
Environmental Protection IP67
Operating Temperature -25°C to +70°C
Storage Temperature -30°C to +70°C
Recommended Humidity 0 to 93% RH @ 40°C
Guarantee 3 years, extended to 5 years upon registration
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Specifications:
Cable Length (Feet): 2.4'
Data Interface: NMEA 0183
Box Dimensions: 2"H x 6"W x 6"L WT: 0.35 lbs
UPC: 5060998710553
Quick Guide (pdf)Owner's Manual (pdf)Brochure (pdf)
SM-3 Replacement BracketReplacement mounting bracket for ACR's SM-3 Marker Light.WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.