Electrical - Terminals
Pacer Seamless Butt Splice - 8 AWG - Non-Insulated - 10 Pack [TBS8-10]
Seamless Butt Splice - 8 AWG - Non-Insulated - 10 PackButt splices are a simple way to repair or create a long-term electrical connection. They are easy to use and built for longevity. Seamless tinned butt splices are available in non-insulated only. How do you use seamless tinned butt splices? The first thing to do is cut and strip your wires to the proper length. Now, if you look inside the butt splice you will see there is an indentation. Insert your wire into the butt splice making sure it butts up to the indentation. Next, simply crimp using the proper tool. This guarantees the correct amount of pressure ensuring a solid connection. Now, simply repeat the process on the other side and you're done. Pacer would strongly recommend performing the tug test. This test ensures that the connection is solid. To do the test simply grab both wires coming out of the butt splice and gently tug two or three times.When using seamless tinned butt splices, make sure you have properly stripped your wires to the correct length. When you look inside of the butt splice, you will see an indentation. Make sure your conductors butt up against that. Insert the wire making sure the insulation touches the butt splice. This reduces the risk of a weaker connection. Now, the splice is crimped with the proper tool. This crimp creates a solid connection. Next, repeat the process on the other side and perform the tug test to make sure that the wires don't pull out. This process creates a durable, lasting connection. Butt splices are used for their rapid installation and durability. Other methods of connection just don't offer the same level of protection.Features: Tin Plated Seamless Specifications: Package Size: 10 Wire AWG: 8 Length: 0.864” I.D. (in.): 0.165” O.D. (in.): 0.295” Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Specifications: Gauge: 8 AWG Heat Shrink: No Box Dimensions: 1"H x 5"W x 9"L WT: 0.1 lbs UPC: 840248206013 Brochure (pdf)
$27.50
Pacer Tinned Lug 1 AWG - 3/8" Stud Size - 10 Pack [TAE1-38R-10]
Tinned Lug 1 AWG - 3/8" Stud Size - 10 PackCreating a strong connection is essential to every electrical system. By using closed-end lugs, users get not only durability but longevity as well. Pacer's closed-end lugs are tin-plated and have no exposed seams. This means that they are ideal for marine applications. What makes them ideal is the fact that they can be used to create waterproof connections. When used with epoxy heat shrink, the closed end lug will fully envelop the conductor. This leaves nothing exposed to the elements. To use, simply strip your wire or cable to the proper length. Once this is complete, slide the lug over the exposed wire, making sure the insulation butts up to the edge of the lug.Now, crimp the lug using the correct tool, and you're done. Add epoxy lined heat shrink for added durability. Pacer's closed-end lugs are available in 8 AWG to 4/0 AWG wire sizes. The available stud sizes include #10, 1/4", 5/16", 3/8", and 1/2". Selecting the correct closed-end lug isn't an easy task. Contact a Pacer expert today with any questions that you may have.Features: Tin Plated No exposed seams Rated for 600V Made from seamless tubes of 99.9% copper for higher conductivity Designed for stranded copper wires Larger pad area for better contact Cable size and stud hole stamped on pad Can be crimped or soldered Highly controlled flare to allow easy cable insertion Tight barrel to pad transition provides longer usable barrel length Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Exceeds SAE Conductivity STD J163 & J1811 Specifications: Wire AWG: 1 Stud Size: 3/8” Length: 1.719” Width: 0.692” Clearance: 0.406” Package Size: 10 Specifications: Gauge: 1 AWG Heat Shrink: No Package Qty: 10 Post Size: 3/8" Type: Lugs Box Dimensions: 1"H x 5"W x 9"L WT: 0.3 lbs UPC: 840248209724 Brochure (pdf)
$19.50
Pacer Tinned Lug 8 AWG - 3/8" Stud Size - 10 Pack [TAE8-38R-10]
Tinned Lug 8 AWG - 3/8" Stud Size - 10 PackCreating a strong connection is essential to every electrical system. By using closed-end lugs, users get not only durability but longevity as well. Pacer's closed-end lugs are tin-plated and have no exposed seams. This means that they are ideal for marine applications. What makes them ideal is the fact that they can be used to create waterproof connections. When used with epoxy heat shrink, the closed end lug will fully envelop the conductor. This leaves nothing exposed to the elements. To use, simply strip your wire or cable to the proper length. Once this is complete, slide the lug over the exposed wire, making sure the insulation butts up to the edge of the lug.Now, crimp the lug using the correct tool, and you're done. Add epoxy lined heat shrink for added durability. Pacer's closed-end lugs are available in 8 AWG to 4/0 AWG wire sizes. The available stud sizes include #10, 1/4", 5/16", 3/8", and 1/2". Selecting the correct closed-end lug isn't an easy task. Contact a Pacer expert today with any questions that you may have.Features: Tin Plated No exposed seams Rated for 600V Made from seamless tubes of 99.9% copper for higher conductivity Designed for stranded copper wires Larger pad area for better contact Cable size and stud hole stamped on pad Can be crimped or soldered Highly controlled flare to allow easy cable insertion Tight barrel to pad transition provides longer usable barrel length Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Exceeds SAE Conductivity STD J163 & J1811 Specifications: Wire AWG: 8 Stud Size: 3/8” Length: 1.344” Width: 0.609” Clearance: 0.406” Package Size: 10 Specifications: Gauge: 8 AWG Heat Shrink: No Package Qty: 10 Post Size: 3/8" Type: Lugs Box Dimensions: 1"H x 5"W x 9"L WT: 0.15 lbs UPC: 840248205955 Brochure (pdf)
$15.50
Pacer Tinned Lug 2 AWG - 1/4" Stud Size - 10 Pack [TAE2-14R-10]
Tinned Lug 2 AWG - 1/4" Stud Size - 10 PackCreating a strong connection is essential to every electrical system. By using closed-end lugs, users get not only durability but longevity as well. Pacer's closed-end lugs are tin-plated and have no exposed seams. This means that they are ideal for marine applications. What makes them ideal is the fact that they can be used to create waterproof connections. When used with epoxy heat shrink, the closed end lug will fully envelop the conductor. This leaves nothing exposed to the elements. To use, simply strip your wire or cable to the proper length. Once this is complete, slide the lug over the exposed wire, making sure the insulation butts up to the edge of the lug.Now, crimp the lug using the correct tool, and you're done. Add epoxy lined heat shrink for added durability. Pacer's closed-end lugs are available in 8 AWG to 4/0 AWG wire sizes. The available stud sizes include #10, 1/4", 5/16", 3/8", and 1/2". Selecting the correct closed-end lug isn't an easy task. Contact a Pacer expert today with any questions that you may have.Features: Tin Plated No exposed seams Rated for 600V Made from seamless tubes of 99.9% copper for higher conductivity Designed for stranded copper wires Larger pad area for better contact Cable size and stud hole stamped on pad Can be crimped or soldered Highly controlled flare to allow easy cable insertion Tight barrel to pad transition provides longer usable barrel length Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Exceeds SAE Conductivity STD J163 & J1811 Specifications: Wire AWG: 2 Stud Size: 1/4” Length: 1.625” Width: 0.609” Clearance: 0.406” Package Size: 10 Specifications: Gauge: 2 AWG Heat Shrink: No Package Qty: 10 Post Size: 1/4" Type: Lugs Box Dimensions: 1"H x 5"W x 9"L WT: 0.25 lbs UPC: 840248209779 Brochure (pdf)
$18.50
Pacer Tinned Lug 4 AWG - 5/16" Stud Size - 10 Pack [TAE4-56R-10]
Tinned Lug 4 AWG - 5/16" Stud Size - 10 PackCreating a strong connection is essential to every electrical system. By using closed-end lugs, users get not only durability but longevity as well. Pacer's closed-end lugs are tin-plated and have no exposed seams. This means that they are ideal for marine applications. What makes them ideal is the fact that they can be used to create waterproof connections. When used with epoxy heat shrink, the closed end lug will fully envelop the conductor. This leaves nothing exposed to the elements. To use, simply strip your wire or cable to the proper length. Once this is complete, slide the lug over the exposed wire, making sure the insulation butts up to the edge of the lug.Now, crimp the lug using the correct tool, and you're done. Add epoxy lined heat shrink for added durability. Pacer's closed-end lugs are available in 8 AWG to 4/0 AWG wire sizes. The available stud sizes include #10, 1/4", 5/16", 3/8", and 1/2". Selecting the correct closed-end lug isn't an easy task. Contact a Pacer expert today with any questions that you may have.Features: Tin Plated No exposed seams Rated for 600V Made from seamless tubes of 99.9% copper for higher conductivity Designed for stranded copper wires Larger pad area for better contact Cable size and stud hole stamped on pad Can be crimped or soldered Highly controlled flare to allow easy cable insertion Tight barrel to pad transition provides longer usable barrel length Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Exceeds SAE Conductivity STD J163 & J1811 Specifications: Wire AWG: 4 Stud Size: 5/16” Length: 1.50” Width: 0.531” Clearance: 0.406” Package Size: 10 Specifications: Gauge: 4 AWG Heat Shrink: No Package Qty: 10 Post Size: 5/16" Type: Lugs Box Dimensions: 1"H x 5"W x 9"L WT: 0.2 lbs UPC: 840248205818 Brochure (pdf)
$17.50
Pacer Tinned Lug 6 AWG - 5/16" Stud Size - 10 Pack [TAE6-56R-10]
Tinned Lug 6 AWG - 5/16" Stud Size - 10 PackCreating a strong connection is essential to every electrical system. By using closed-end lugs, users get not only durability but longevity as well. Pacer's closed-end lugs are tin-plated and have no exposed seams. This means that they are ideal for marine applications. What makes them ideal is the fact that they can be used to create waterproof connections. When used with epoxy heat shrink, the closed end lug will fully envelop the conductor. This leaves nothing exposed to the elements. To use, simply strip your wire or cable to the proper length. Once this is complete, slide the lug over the exposed wire, making sure the insulation butts up to the edge of the lug.Now, crimp the lug using the correct tool, and you're done. Add epoxy lined heat shrink for added durability. Pacer's closed-end lugs are available in 8 AWG to 4/0 AWG wire sizes. The available stud sizes include #10, 1/4", 5/16", 3/8", and 1/2". Selecting the correct closed-end lug isn't an easy task. Contact a Pacer expert today with any questions that you may have.Features: Tin Plated No exposed seams Rated for 600V Made from seamless tubes of 99.9% copper for higher conductivity Designed for stranded copper wires Larger pad area for better contact Cable size and stud hole stamped on pad Can be crimped or soldered Highly controlled flare to allow easy cable insertion Tight barrel to pad transition provides longer usable barrel length Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Exceeds SAE Conductivity STD J163 & J1811 Specifications: Wire AWG: 6 Stud Size: 5/16” Length: 1.266” Width: 0.438” Clearance: 0.344” Package Size: 10 Specifications: Gauge: 6 AWG Heat Shrink: No Package Qty: 10 Post Size: 5/16" Type: Lugs Box Dimensions: 1"H x 5"W x 9"L WT: 0.15 lbs UPC: 840248205894 Brochure (pdf)
$17.50
Pacer Tinned Lug 1/0 AWG - 3/8" Stud Size - 10 Pack [TAE1/0-38R-10]
Tinned Lug 1/0 AWG - 3/8" Stud Size - 10 PackCreating a strong connection is essential to every electrical system. By using closed-end lugs, users get not only durability but longevity as well. Pacer's closed-end lugs are tin-plated and have no exposed seams. This means that they are ideal for marine applications. What makes them ideal is the fact that they can be used to create waterproof connections. When used with epoxy heat shrink, the closed end lug will fully envelop the conductor. This leaves nothing exposed to the elements. To use, simply strip your wire or cable to the proper length. Once this is complete, slide the lug over the exposed wire, making sure the insulation butts up to the edge of the lug.Now, crimp the lug using the correct tool, and you're done. Add epoxy lined heat shrink for added durability. Pacer's closed-end lugs are available in 8 AWG to 4/0 AWG wire sizes. The available stud sizes include #10, 1/4", 5/16", 3/8", and 1/2". Selecting the correct closed-end lug isn't an easy task. Contact a Pacer expert today with any questions that you may have.Features: Tin Plated No exposed seams Rated for 600V Made from seamless tubes of 99.9% copper for higher conductivity Designed for stranded copper wires Larger pad area for better contact Cable size and stud hole stamped on pad Can be crimped or soldered Highly controlled flare to allow easy cable insertion Tight barrel to pad transition provides longer usable barrel length Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Exceeds SAE Conductivity STD J163 & J1811 Specifications: Wire AWG: 1/0 Stud Size: 3/8” Length: 1.844” Width: 0.734” Clearance: 0.406” Package Size: 10 Specifications: Gauge: 1/0 AWG Heat Shrink: No Package Qty: 10 Post Size: 3/8" Type: Lugs Box Dimensions: 1"H x 5"W x 9"L WT: 0.4 lbs UPC: 840248205375 Brochure (pdf)
$25.50
Pacer Tinned Lug 1 AWG - 1/4" Stud Size - 10 Pack [TAE1-14R-10]
Tinned Lug 1 AWG - 1/4" Stud Size - 10 PackCreating a strong connection is essential to every electrical system. By using closed-end lugs, users get not only durability but longevity as well. Pacer's closed-end lugs are tin-plated and have no exposed seams. This means that they are ideal for marine applications. What makes them ideal is the fact that they can be used to create waterproof connections. When used with epoxy heat shrink, the closed end lug will fully envelop the conductor. This leaves nothing exposed to the elements. To use, simply strip your wire or cable to the proper length. Once this is complete, slide the lug over the exposed wire, making sure the insulation butts up to the edge of the lug.Now, crimp the lug using the correct tool, and you're done. Add epoxy lined heat shrink for added durability. Pacer's closed-end lugs are available in 8 AWG to 4/0 AWG wire sizes. The available stud sizes include #10, 1/4", 5/16", 3/8", and 1/2". Selecting the correct closed-end lug isn't an easy task. Contact a Pacer expert today with any questions that you may have.Features: Tin Plated No exposed seams Rated for 600V Made from seamless tubes of 99.9% copper for higher conductivity Designed for stranded copper wires Larger pad area for better contact Cable size and stud hole stamped on pad Can be crimped or soldered Highly controlled flare to allow easy cable insertion Tight barrel to pad transition provides longer usable barrel length Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Exceeds SAE Conductivity STD J163 & J1811 Specifications: Wire AWG: 1 Stud Size: 1/4” Length: 1.719” Width: 0.692” Clearance: 0.406” Package Size: 10 Specifications: Gauge: 1 AWG Heat Shrink: No Package Qty: 10 Post Size: 1/4" Type: Lugs Box Dimensions: 1"H x 5"W x 9"L WT: 0.45 lbs UPC: 840248209717 Brochure (pdf)
$19.50
Pacer Tinned Lug 6 AWG - 1/4" Stud Size - 10 Pack [TAE6-14R-10]
Tinned Lug 6 AWG - 1/4" Stud Size - 10 PackCreating a strong connection is essential to every electrical system. By using closed-end lugs, users get not only durability but longevity as well. Pacer's closed-end lugs are tin-plated and have no exposed seams. This means that they are ideal for marine applications. What makes them ideal is the fact that they can be used to create waterproof connections. When used with epoxy heat shrink, the closed end lug will fully envelop the conductor. This leaves nothing exposed to the elements. To use, simply strip your wire or cable to the proper length. Once this is complete, slide the lug over the exposed wire, making sure the insulation butts up to the edge of the lug.Now, crimp the lug using the correct tool, and you're done. Add epoxy lined heat shrink for added durability. Pacer's closed-end lugs are available in 8 AWG to 4/0 AWG wire sizes. The available stud sizes include #10, 1/4", 5/16", 3/8", and 1/2". Selecting the correct closed-end lug isn't an easy task. Contact a Pacer expert today with any questions that you may have.Features: Tin Plated No exposed seams Rated for 600V Made from seamless tubes of 99.9% copper for higher conductivity Designed for stranded copper wires Larger pad area for better contact Cable size and stud hole stamped on pad Can be crimped or soldered Highly controlled flare to allow easy cable insertion Tight barrel to pad transition provides longer usable barrel length Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Exceeds SAE Conductivity STD J163 & J1811 Specifications: Wire AWG: 6 Stud Size: 1/4” Length: 1.266” Width: 0.438” Clearance: 0.344” Package Size: 10 Specifications: Gauge: 6 AWG Heat Shrink: No Package Qty: 10 Post Size: 1/4" Type: Lugs Box Dimensions: 1"H x 5"W x 9"L WT: 0.15 lbs UPC: 840248209830 Brochure (pdf)
$20.50
Pacer Tinned Lug 1/0 AWG - 1/4" Stud Size - 10 Pack [TAE1/0-14R-10]
Tinned Lug 1/0 AWG - 1/4" Stud Size - 10 PackCreating a strong connection is essential to every electrical system. By using closed-end lugs, users get not only durability but longevity as well. Pacer's closed-end lugs are tin-plated and have no exposed seams. This means that they are ideal for marine applications. What makes them ideal is the fact that they can be used to create waterproof connections. When used with epoxy heat shrink, the closed end lug will fully envelop the conductor. This leaves nothing exposed to the elements. To use, simply strip your wire or cable to the proper length. Once this is complete, slide the lug over the exposed wire, making sure the insulation butts up to the edge of the lug.Now, crimp the lug using the correct tool, and you're done. Add epoxy lined heat shrink for added durability. Pacer's closed-end lugs are available in 8 AWG to 4/0 AWG wire sizes. The available stud sizes include #10, 1/4", 5/16", 3/8", and 1/2". Selecting the correct closed-end lug isn't an easy task. Contact a Pacer expert today with any questions that you may have.Features: Tin Plated No exposed seams Rated for 600V Made from seamless tubes of 99.9% copper for higher conductivity Designed for stranded copper wires Larger pad area for better contact Cable size and stud hole stamped on pad Can be crimped or soldered Highly controlled flare to allow easy cable insertion Tight barrel to pad transition provides longer usable barrel length Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Exceeds SAE Conductivity STD J163 & J1811 Specifications: Wire AWG: 1/0 Stud Size: 1/4” Length: 1.844” Width: 0.734” Clearance: 0.406” Package Size: 10 Specifications: Gauge: 1/0 AWG Heat Shrink: No Package Qty: 10 Post Size: 1/4" Type: Lugs Box Dimensions: 1"H x 5"W x 9"L WT: 0.3 lbs UPC: 840248209687 Brochure (pdf)
$24.50
Pacer Tinned Lug 2 AWG - 3/8" Stud Size - 10 Pack [TAE2-38R-10]
Tinned Lug 2 AWG - 3/8" Stud Size - 10 PackCreating a strong connection is essential to every electrical system. By using closed-end lugs, users get not only durability but longevity as well. Pacer's closed-end lugs are tin-plated and have no exposed seams. This means that they are ideal for marine applications. What makes them ideal is the fact that they can be used to create waterproof connections. When used with epoxy heat shrink, the closed end lug will fully envelop the conductor. This leaves nothing exposed to the elements. To use, simply strip your wire or cable to the proper length. Once this is complete, slide the lug over the exposed wire, making sure the insulation butts up to the edge of the lug.Now, crimp the lug using the correct tool, and you're done. Add epoxy lined heat shrink for added durability. Pacer's closed-end lugs are available in 8 AWG to 4/0 AWG wire sizes. The available stud sizes include #10, 1/4", 5/16", 3/8", and 1/2". Selecting the correct closed-end lug isn't an easy task. Contact a Pacer expert today with any questions that you may have.Features: Tin Plated No exposed seams Rated for 600V Made from seamless tubes of 99.9% copper for higher conductivity Designed for stranded copper wires Larger pad area for better contact Cable size and stud hole stamped on pad Can be crimped or soldered Highly controlled flare to allow easy cable insertion Tight barrel to pad transition provides longer usable barrel length Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Exceeds SAE Conductivity STD J163 & J1811 Specifications: Wire AWG: 2 Stud Size: 3/8” Length: 1.625” Width: 0.609” Clearance: 0.406” Package Size: 10 Specifications: Gauge: 2 AWG Heat Shrink: No Package Qty: 10 Post Size: 3/8" Type: Lugs Box Dimensions: 1"H x 5"W x 9"L WT: 0.25 lbs UPC: 840248205610 Brochure (pdf)
$27.50
Pacer Tinned Lug 2/0 AWG - 1/4" Stud Size - 10 Pack [TAE2/0-14R-10]
Tinned Lug 2/0 AWG - 1/4" Stud Size - 10 PackCreating a strong connection is essential to every electrical system. By using closed-end lugs, users get not only durability but longevity as well. Pacer's closed-end lugs are tin-plated and have no exposed seams. This means that they are ideal for marine applications. What makes them ideal is the fact that they can be used to create waterproof connections. When used with epoxy heat shrink, the closed end lug will fully envelop the conductor. This leaves nothing exposed to the elements. To use, simply strip your wire or cable to the proper length. Once this is complete, slide the lug over the exposed wire, making sure the insulation butts up to the edge of the lug.Now, crimp the lug using the correct tool, and you're done. Add epoxy lined heat shrink for added durability. Pacer's closed-end lugs are available in 8 AWG to 4/0 AWG wire sizes. The available stud sizes include #10, 1/4", 5/16", 3/8", and 1/2". Selecting the correct closed-end lug isn't an easy task. Contact a Pacer expert today with any questions that you may have.Features: Tin Plated No exposed seams Rated for 600V Made from seamless tubes of 99.9% copper for higher conductivity Designed for stranded copper wires Larger pad area for better contact Cable size and stud hole stamped on pad Can be crimped or soldered Highly controlled flare to allow easy cable insertion Tight barrel to pad transition provides longer usable barrel length Compliances: E.T.P. (Electrolytic Tough Pitch) CDA-110 ASTM-B-152 copper rated at 100% conductivity UL & CSA Approved RoHS Compliant Exceeds SAE Conductivity STD J163 & J1811 Specifications: Wire AWG: 2/0 Stud Size: 1/4” Length: 2.063” Width: 0.813” Clearance: 0.500” Package Size: 10 Specifications: Gauge: 2 AWG Heat Shrink: No Package Qty: 10 Post Size: 1/4" Type: Lugs Box Dimensions: 1"H x 5"W x 8"L WT: 0.5 lbs UPC: 840248209748 Brochure (pdf)
$23.50