Max Charge MC-618 Regulator 12V with Harness Multi-StageThe MC-618-H premium 12-volt multi-stage voltage regulator provides the ultimate in charging safety and control. Includes wiring harness. Features:
Intelligent multi-stage regulation.
Digital numeric LED display.
Epoxy-encapsulated circuitry.
For use with 12 volt systems
Wiring harness included
Can be used to drive twin alternator installations.
For use with P-type externally regulated alternators
Dash lamp and auxiliary lamp terminals
Small engine mode
Magnetic programming tool included
LiFePo4 (lithium) program
Optional alternator and battery temperature sensors sold separately
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns.
SmartSolar MPPT Charge Controller - 100V - 30AMPFeatures:
Bluetooth Smart built-in The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers.
VE.Direct For a wired data connection to a Color Control GX, other GX products, PC or other devices
Ultra-fast Maximum Power Point Tracking (MPPT) Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers.
Load output Over-discharge of the battery can be prevented by connecting all loads to the load output. The load output will disconnect the load when the battery has been discharged to a pre-set voltage (48V model: interface with a relay). Alternatively, an intelligent battery management algorithm can be chosen: see Battery Life. The load output is short circuit proof.
Battery Life: intelligent battery management When a solar charge controller is not able to recharge the battery to its full capacity within one day, the result is often that the battery will continually be cycled between a ‘partially charged’ state and the ‘end of discharge’ state. This mode of operation (no regular full recharge) will destroy a lead-acid battery within weeks or months. The Battery Life algorithm will monitor the state of charge of the battery and, if needed, day by day slightly increase the load disconnect level (i.e. disconnect the load earlier) until the harvested solar energy is sufficient to recharge the battery to nearly the full 100%. From that point onwards, the load disconnect level will be modulated so that a nearly 100% recharge is achieved about once every week.
Programmable battery charge algorithm See the software section on our website for details
Day/night timing and light dimming option See the software section on our website for details
Internal temperature sensor Compensates absorption and float charge voltage for temperature.
Optional external battery voltage and temperature sensing via Bluetooth A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage and temperature to one or more SmartSolar Charge Controllers
Warranty InfoWARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.Please contact your dealer for any returns, repairs or support issues related to this product. Specifications:
Charger Input - Voltage: 18-100v
Charger Output - Amps: 30a
Charger Output Voltage: 12v/24v
Charging Banks: 1
Portable: No
Box Dimensions: 4"H x 5"W x 8"L WT: 3.1 lbs
UPC: 8719076040170
Quick Guide (pdf)Brochure (pdf)
RJ45 UTP - 10M CableA cable to connect Phoenix Inverter Control, VE Interface MK3-USB, and VE.Bus connections between multiple VE.Bus devices and GX devices.Warranty InfoWARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.Please contact your dealer for any returns, repairs or support issues related to this product. Quick Guide (pdf)
Yellow 8 AWG Tinned Copper Wire - 50'Ancor Marine Grade wire products are the longest lasting and most rugged available, exceeding UL 1426, ABYC, and US Coast Guard Charter boat (CFR Title 46) standards. They are constructed with premium vinyl insulation that is rated at 600V, 105°C dry and 75°C wet, stays flexible even in extreme cold (-40°F/C), and resists salt water, battery acid, oil, gasoline, heat, abrasion, and ultraviolet radiation. Highest quality ultra-flexible (Type 3) tinned copper stranding provides maximum protection against corrosion and electrolysis while resisting fatigue due to vibration and flexing.Specifications:
Wire Gauge: 8 AWG
Color: Yellow
Length: 50'
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Length (Feet): 50'
Gauge: 8 AWG
Color: Yellow
Box Dimensions: 5"H x 7"W x 7"L WT: 3.95 lbs
UPC: 091887967685
ST Blade Fuse Block w/o Cover - 6 Circuit w/o Negative BusPart# 5037
Can be used for 24-hour circuits
Fuse blocks with covers include 20 write-on circuit labels
Tin-plated copper buses and fuse clips
Accepts ring or spade type terminals
Accepts ATO® and ATC® fast acting blade fuses
Fuses sold separately
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Fuse Type: ATO/ATC
Type: Fuse Blocks
Box Dimensions: 2"H x 4"W x 8"L WT: 0.35 lbs
UPC: 632085050375
Owner's Manual (pdf)
HD-Series Battery Switch Single Circuit ON/OFFFeatures:
600 Ampere Continuous Rating
Accepts two 4/0 battery cables per terminal
Ignition protected - safe for installation aboard gasoline-powered boats
.870" (22.01mm) stud length to accept multiple cable terminals
1/2" (M12) Tin-plated copper studs for maximum conductivity and corrosion resistance
Meets American Boat and Yacht Council (ABYC) requirements for battery switches
Tactile textures indicate knob position by feel only
Case design allows surface or rear panel mounting
Fits all Perko and Guest low amperage battery switch hole patterns
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Positions: 2
AFD: No
Continuous Amperage: 900a
Box Dimensions: 3"H x 7"W x 9"L WT: 1.3 lbs
UPC: 632085030001
Owner's Manual (pdf)
5029ST Blade Fuse Block w/ Cover - 12 Circuit w/out Negative Bus
Clear insulating cover with label recesses accept Small Format Labels
Cover Satisfies ABYC/USCG requirements for insulation
Tin-plated copper buses and fuse clips give 30 Amperes rating per circuit
Accepts ATO and ATC fast acting blade fuses
20 write-on circuit labels included
Tin-plated copper buses and fuse clips give 30 Amperes rating per circuit
Accepts ATO and ATC fast acting blade fuses
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Fuse Type: ATO/ATC
Type: Fuse Blocks
Box Dimensions: 2"H x 4"W x 8"L WT: 0.6 lbs
UPC: 632085050290
Quick Guide (pdf)
9009Switch, AC 120VAC
Amperes
32
Positions
2+OFF
Poles
2
Switches 2 - 120 or 230 Volt AC sources
Compact solution when circuit protection is provided elsewhere
Allows connecting one of two different AC sources to one circuit
Mounts in panels up to 0.16" (4.00mm) thick
Heavy duty industrial rated switch
Intuitive function - One hand operation
UL listed
600 Volt AC max
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Color: Black
Box Dimensions: 4"H x 5"W x 7"L WT: 0.5 lbs
UPC: 632085090098
Owner's Manual (pdf)
8058 AC 3 Position Toggle Circuit Breaker Panel - White SwitchesFeatures:
All hot, neutral, and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit posistions
Maximum panel amperage - 100 Amperes
Specifications:
Positions: 3
Nominal Voltage: 120v AC
Maximum Amperage: 100A
Height: 3.75"
Width: 5.25"
Included:
(3) 7210 A-Series White Toggle Circuit Breaker - Single Pole 15A
(1) 8031 Basic AC Panel Label Set - 30 Labels
(3) 8034 LED - 120V AV Green
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
AC/DC: AC
Max Breaker Quantity: 3
Voltage: 120v
Box Dimensions: 5"H x 7"W x 9"L WT: 1.2 lbs
UPC: 632085080587
Owner's Manual (pdf)
187 - Series Thermal Circuit Breakers - Surface Mount25 Amp Circuit BreakerPN: 7135Features:
Combines switching and circuit protection into a single device
All components meet SAE J1171 external ignition protection requirements
Clear, single lever operation
"Trip Free" design cannot be held "ON" during fault current condition
Waterproof
Recessed mounting holes for clean appearance
Large clearance around terminal studs accept heavy gauge wire lugs
Robust 5/16 terminals provide high torque connections
Large lever with vertical/horizontal orientation provides indication of trip status
Ignition protected - safe for installation aboard gasoline powered boats
Specifications
Circuit Breaker Class:
Type III - Switchable / Manual Reset - Trip Free
Type:
Thermally Responsive Bi-Metal Blade
Case Material:
Thermoset Polyester
Voltage Rating:
48 Volts DC Maximum
Interrupt Rating:
5,000 Amperes @12 Volts DC
3,000 Amperes @24 Volts DC
1,500 Amperes @42 Volts DC
Operating Temperature Range:
-25C° to +82C°
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Amperage: 25a
Box Dimensions: 2"H x 5"W x 8"L WT: 0.6 lbs
UPC: 632085071356
2104 PowerBar 600AMP Cable Connector 4 x 3/8 16 Stud TerminalSpecifications:
Max Voltage: 300 V AC/48 V DC
Number of Terminal Studs: 4
Terminal Type: 3/8" - 16 Stud
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
2708 BusBar Cover for PowerBar 2104Specifications:Dimensions: 8.500" x 3.375" x 2.750"WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.