32-12-35 DC ConverterConvert 20-50 VDC input to 12 VDC negative ground output for powering communication and navigation equipment on negative ground systems. (See Isolated Series for positive ground applications.)Features:
Excellent Regulation: Output voltage maintained within 1% under all line and load conditions within the rating
The heat generated by semi-conductors is extracted and dissipated by large heat sink fins that maximize air contact for cool operation and the long life of components
Polyurethane conformal coating on PC boards and corrosion-resistant anodized aluminum cases with heavy-duty shock mounts assure survival in hostile environments
Numerous Converter & Load Protection Circuits:
Current limiting
Automatic thermal shutdown
Short circuit proof
Reverse polarity
Overvoltage protection
Carries CE mark
Specifications:
Input Voltage: 20-50
Output Voltage: 13.6
Output Amps (Intermittent): 35
Output Amps (Continuous): 30
Case Size (H x W x D): 6.0 x 4.7 x 16.0 inches (15.2 x 11.9 x 40.6 centimeters)
Weight: 12 lb. (5.5 kg)
Output: 13.6 VDC (internally adjustable 12.6 -14.5) or 24.5 VDC (or specify)
Ripple: 150 mV P-P maximum
Regulation: 1% Line/Load
Switching Frequency: 40 kHz
Efficiency: 85% – Typical.
Isolation: Output/Chassis; Input/chassis: 250 VDC
Duty Cycle Ratings*:
Intermittent: 20 minutes max on time, 20% duty. current limit set at approx. 105% of intermittent rating.
Continuous: 24 hours, 100% duty *24-12-3: 2-minute max. on time
Idle Current: Less than 100 mA (including power “ON” light)
Operating Temp Specifications:
0-50 degrees C, Derate Linearly From 100% @ 40 degrees C To 50% @ 50 degrees C.
Thermal shutdown @ 70 degrees C Case Temperature
Model 24-12-3: Full output -25 degrees to +30 degrees C; Derate linearly from 100% @ +30 degrees C to 45% @ +50 degrees C
Mechanical Specifications:
Powder-coated aluminum heat sink case
Front panel terminal block
Heavy-duty mounting flange
Conformal coated PC board
Options:
Operation as a battery charger or parallel redundant operation* – derate to continuous duty rating (contact factory)
Extreme vibration mounting kit. (Information below)
Option: Extreme Vibration Mounting KitThe Extreme Vibration Mounting Kit is available to protect NEWMAR power converters from the extreme stresses of shock and vibration when mounted on high-vibration vehicles. The kit replaces the standard vibration kit provided with the unit. It fits into the unit’s mounting flange to act as a ‘super shock absorber’ for electronics in high-vibration applications. It is available to fit all NEWMAR units from 2 to 70 lbs. Specify KIT L for units that weigh 2–15 lbs. and Kit H for 16–7 lbs.This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns.
TDR Series Dual Output Time Delay Relay 12V (2 x 80A)This 12V dual-time relay can prevent dead batteries due to added equipment loads on after-engine stops or from multiple systems connected to a battery with an independent keep-alive power draw, maximizing operational readiness.Applications:
Supports on-board video systems when vehicles are not in use, allowing lengthy downloading while shutting down less time-sensitive equipment. sooner.
Protects sensitive onboard electronics via optional under/over voltage shutdown and start event isolation.
Features:
Eliminates vehicle downtime due to dead batteries; the lowest off-state current draw (1.3 mA) is available
Simple and robust Installation - Sealed plug with optional long wire leads; Single device replaces multiple control units and high-amp replays reduce installation time, costs, and points of potential failure
Additional low-amp output can be used to maintain 24-hour memory circuits or to direct other equipment to shut down
Bullet-proof construction - Sealed unit and high-temperature materials allow mounting anywhere on the vehicle; Integrated thermal overload protection as well
Meets stringent OEM standards for electrical transient self-protection
Adjustable OFF Time Delay - 0 seconds to 4 hours
Kill Switch control input option for ensuring loads are not inadvertently on, maintenance/servicing of vehicles, and emergency OFF
Flexible control options via ignition key, alternator voltage sense, or both
4 Year Industry Leading Warranty
Specifications:
Maximum Current: Continuous: 80 Amps DC per Output (160 A Total); Intermittent: 120 Amps DC (5 Minutes) per Output
Off-State Current Draw: 1.5 mA (less than 1 Amp-hr battery dissipation per month of stand-by)
Operating Specifications: Voltage: 12 Vdc Nominal (8 - 18 Vdc); Temperature: -40 to 85 degrees C
Time Delay Options: 5 Sec through 4 hours via Dip Switches
Environment Protection Standards: Waterproof to IP66. IP6K9K; Ignition Protected to ISO 8846
Optional Features: Input stud voltage sense trigger for relay OFF; Under-voltage and over-voltage load protection
Focal Features:Top Side Dip SwitchesAccessible after installation, for programming time delay and determining active features. Protected by self-retained cover.Stainless Steel Self-Locking Hardware 100% Non-ferrous corrosion-resistant materials. All attachment screws and nuts are self-locking.Integral I/O Connector Rapid and 100% correct assembly via Molex MX-150 connector eliminates poor field connections.Standard and Optional Harnesses The mating plugs with 2 feet of the ground and ignition wire included. Optional harnesses with additional outputs and alternate wire lengths are availableEasy Integration with CT Fuse Blocks Optional EasyLink bus bars reduce the space and cost of connecting TDRs with CT series Fuse Blocks.Easy Integration with RT Fuse Blocks Optional EasyLink bus bars reduce the space and cost of connecting TDRs with RT series Fuse Blocks.LED DiagnosticsIndicates a pending relay OFF event due to under/over voltage or external off trigger. Output on/off status is also provided.WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Quick Guide (pdf)
BB-2/8 Bus BarIdeal as a DC ground tie point or positive bus, this heavy-duty, 500-amp-rated bus bar assembly features 5/16 in. studs on 1 in. centers in 1/4 in. thick copper bar for common connection or distribution of large wire gauges.Features:
Accommodate 5/16" ring terminals
Insulated base (reinforced nylon resin with a clear protective cover)
Specifications:
Quantity of 5/16" Studs: 2 plus 8 – #8 screws
Size (inches): 6-1/16” x 1-1/2”
2-3-70 Battery IsolatorThis heavy-duty isolator allows charging multiple batteries automatically from one or two alternators and prevents the discharge or ‘dumping” of one battery into another. Each battery is charged according to its need without overcharging and is rated for 12-, 24-, or 36-volt negative ground DC systems. Features:
Conservatively rated diodes and a rustproof anodized aluminum heat sink case.
Heavy-duty construction
Rated for systems up to 48 volts DC, negative ground
Rust-proof anodized aluminum case
Stainless steel mounting hardware is provided
Protective covers are provided for terminals
Specifications:
Alternator Sources: 2
Battery Bank: 3
Max. Amperage Input Capacity: 70
Stud Terminal Size: 6mm
Dimensions (L x W x H): 6.5 x 4.5 x 3.1 inches
Weight: 4 lbs.
Operating Temperature: -40 to +80 degrees
Duty Cycle: Continuous rating to 50 degrees C Derate linearly to 70% @ 80 degrees C.
Temp. Rise: 5 degrees C at full rated current (mount vertically for optimum cooling)
Voltage Drop: 0.7V @ 50% load, 0.9V @ full load
*Note: These battery isolators are not compatible with self-exciting alternators. The alternator must have an external excitation lead. Please consult the manufacturer of your alternator if you are unsure of your configurationThis product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Quick Guide (pdf)
AC-IX PanelEssential control and protection whenever AC from shore power or generators is on board. A double-pole master breaker with a power-on indicator light protects both the hot and neutral legs of the AC circuit. A reverse polarity light provides a clear warning when wiring is reversed and poses a shock hazard.AC-IX is a 30 amp master breaker (15A or 50 A* optional), 5 branch circuit capacity, 4 installed standard 1-10A, 2-15A, 1-20A, or specify. LS-I label set is included. Specifications:
Cut-Out Dimensions: 4 x 6 inches (10.2 x 15.2 centimeters)
Weight: 2 lbs.
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns.
CCX-T Thru-Dex FittingThis waterproof fitting's entry hole is pre-drilled in seal with a slit edge allowing feed through of cable with a factory-installed connector attached. One CCX fitting is required for each cable.Features:
Create a 100% waterproof seal when routing cables through decks and bulkheads
Entry hole predrilled in seal with a slit to edge
Allowing installation or removal with the connector still attached
Rugged weatherproof nylon housing with neoprene seal
Specifications:
Cable Diameter Range (inches): .18-.35
Max Connector Diameter (inches): .83
Specifications:
Type: Deck Seal
Box Dimensions: 2"H x 4"W x 7"L WT: 0.2 lbs
12-12-6i Power StabilizerFeed sensitive electronics with proper voltage, regardless of the battery condition. This stabilizing converter provides continuous, precisely regulated output over the entire range of a battery’s usable voltage. This prevents subjecting loads to fluctuating input voltage, which can cause shutdown, diminish performance, and possibly damage sensitive circuitry.This converter provides total input/output isolation, virtually eliminating conducted line noise and permitting the connection of negative ground gear to positive or floating ground systems, or vice versa. It can be modified for use as a battery charger, allowing them to maintain a battery at a great distance from the primary voltage source, providing reserve power if the main source fails. The rugged anodized aluminum case is ideal for marine applications.Application Benefits Include:
Operate electronics at optimal input voltage, even from nearly drained batteries
Boost voltage to compensate for voltage drops in long wire runs from batteries
Eliminate voltage drops during momentary high current drain from batteries, as during engine start
Eliminate voltage fluctuation from charge sources
Eliminate voltage overshoot due to sudden removal of high current load
Specifications:
Input Voltage: 10-16
Input Amps: 8
Output Voltage: 13.6
Output Amps (Intermittent): 6
Output Amps (Continuous): 6
Case Size (H x W x D): 6.5 x 4.0 x 1.75 inches (6.8 x 10.2 x 4.5 centimeters)
Weight: 2 lb. (.9 kg)
Output: 12 or 24V, nominal, see matrix
Ripple: 150 mV P-P maximum
Regulation: 1% Line/Load
Duty Cycle Ratings:
Intermittent: 20 minutes max on time, 20% duty. The current limit is set at approx. 105% of intermittent rating.
Continuous: 24 hours, 100% duty
Idle Current: Less than 100 mA (including power “ON” light )
Operating Temp: 0-50 degrees C, Derate Linearly From 100% @ 40 degrees C To 50% @ 50 degrees C. Thermal shutdown @ 70 degrees C Case Temperature.
Switching Frequency: 40 kHz.
Efficiency: 85% – Typical.
Isolation – Output/Chassis; Input/chassis: 250 VDC
Mechanical Specifications:
Anodized aluminum heat sink case
Front panel terminal block
Heavy-duty mounting flange
Conformal-coated PC board
Options/Factory Modifications:
Operation as a battery charger (contact factory)
Parallel/redundant operation (contact factory)
High-vibration mounting kit
Non-standard output voltage (contact factory)
Option: Extreme Vibration Mounting KitThe Extreme Vibration Mounting Kit is available to protect NEWMAR power converters from the extreme stresses of shock and vibration when mounted on high-vibration vehicles.The kit (pictured here) replaces the standard vibration kit provided with the unit and fits into the unit’s mounting flange to act as a “super shock absorber” for electronics in high-vibration applications. It is available to fit all NEWMAR units from 2 to 70 lbs. Specify KIT–L for units that weigh 2–15 lbs. and Kit–H for units that weigh 16-70 lbs.This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns.
ACCY-IBX Blank PanelThis versatile panel is ideal when only a limited number of electrical circuits are needed or for larger systems where their modular design makes for an easy and attractive expansion of existing system capacity.Stock panels with breakers installed come standard with DC indicator lights but may be specially ordered with AC indicator lights. Blank versions of the panels have all the necessary hardware to install indicator lights and breakers. All panels are provided with a circuit identification label set of 22 common on-board electrical functions. ACCY-IBX is a blank version of ACCY-IX. No breakers or indicator lights are provided. Label set, indicator light, and breaker mounting hardware are provided.Specifications:
Cut-Out Dimensions: 4 x 6 inches (10.2 x 15.2 centimeters)
Weight: 1 lb.
CCX-S Thru-Dex FittingThis waterproof fitting's entry hole is pre-drilled in seal with a slit edge allowing feed through of cable with a factory-installed connector attached. One CCX fitting is required for each cable.Features:
Create a 100% waterproof seal when routing cables through decks and bulkheads
Entry hole predrilled in seal with a slit to edge
Allowing installation or removal with the connector still attached
Rugged weatherproof nylon housing with neoprene seal
Specifications:
Cable Diameter Range (inches): .35-.55
Max Connector Diameter (inches): .83
Specifications:
Type: Deck Seal
Box Dimensions: 1"H x 4"W x 7"L WT: 0.2 lbs
200A Circuit Breaker - 85 Series - Surface MountFeatures:
Sealed Against Dust & Water Intrusion to ensure reliable circuit protection for the life of the electrical system installation.
Up to 30 Volt-rated easily supports 12 Vdc (200 & 250 A) and 24 Vdc (200 A) applications.
High Interrupt Current safely protects circuits connected to large paralleled battery banks with significant available power.
Ignition-protected safe for installation in closed compartments with potential explosive gases.
Harsh Environment design with stainless steel hardware, serrated flange nuts, and silicone terminal covers.
Specifications:
Amperage: 200a
Box Dimensions: 3"H x 5"W x 6"L WT: 0.45 lbs
UPC: 850035199695
Brochure (pdf)
RT Fuse Block 12 Position with Ground & LED IndicationThis 12-position fuse block has a modular design that can produce seven (7) unique configurations from Egis 8028 & 8030 and reduce part numbers to stock for all build requirements. Also, this fuse block has a ground and LED indication.Applications:
Blown fuse LEDs speed up the correction of system faults and improve the ability to remotely diagnose customer issues.
Harsh environment design with stainless steel self-locking hardware and optional weather-proof labels in standard or customized options.
Features:
Bullet-proof construction - designed with high-temperature materials and stainless steel self-locking hardware allows mounting anywhere on the vehicle
Protects branch circuits by accepting ATO style fuses ranging from 1 through 40 Amps
Supports SAE circuit protection standards for thermal/short circuit events
Specifications:
Maximum Current (Entire Block) Amps: 10
Maximum Current (Per Circuit) Amps: 30
Max Output Wire Size: #10 AWG
Voltage Range VDC: 0-36
Number of Fuse Positions: 12
Compatible Fuse Types: ATO / ATC / ATF
Focal Features:Spare Fuse LocationsTwo locations per 6 circuits for spare or test resistors to reduce siren volumes during evaluation.Stainless Steel Self-Locking Hardware100 % non-ferrous corrosion-resistant materials. All attachment screws and nuts are self-locking.LED Fuse DiagnosticsBlown fuse LED indication for each output circuit provides a clear indication of faulty circuits and eases troubleshooting issues remotely.Cover/ Label RecessesProtects terminal studs and cable terminal edges from inadvertent shorts to each other or ground.Ground Block IncludedIncludes a 12-position ground return block with multi-level low amp terminal screws for improved mounting.Ground Block SeparatesThe ground block section optionally separates from the fuse block section, affording increased deployment options for challenging installations.WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Amperage: 100a
Fuse Type: ATO/ATC/ATF
Type: Fuse Blocks
Box Dimensions: 3"H x 4"W x 8"L WT: 1 lbs
UPC: 850035199725
Quick Guide (pdf)
MT Series 3+9 Sealed Fuse Block with Ground BusbarFeatures:
Integrated Deutsch/Amphenol Output Connectors
Protects add-On Circuits From Accidental Shorts To Frame Ground Or Battery Negative, Or From Overload Events
Expandable with Flex System Compatible Interconnect Busbars For Plug-and-Play Install
Split Input 3+9 Circuits
*Fuses and Circuit Breakers Sold Separately Brochure (pdf)