MPower 12 Channel DC Load Module NMEA 2K with 12" Pigtail Adapter Cable for J1 & J2 ConnectorsDesigned for vessels of all sizes with smaller loads, the MPower® CLMD12 is a compact 12-Channel DC Load Controller Module. Two of the 12 breakers handle a maximum of 12 amps, six handle a maximum of 10 amps, and four handle a maximum of 5 amps, with a total current capacity of 75 Amps. Additionally, circuits can be paralleled.If a smaller circuit needs to be protected, each of the 12 breakers can be set to trip at lower current levels using the new Maretron N2KAnalyzer® V3 software. In addition, the CLMD12 has inputs for up to 7 hard-wired switches that can be used to switch breaker states, or as inputs for other data, such as bilge alarms or hatch positions, etc.The CLMD12 handles many DC load types such as lights, pumps, motors, and electronics. An added benefit of the CLMD12 is that it reports the current through each of the 12 breakers. This allows you to determine if loads are drawing too much or too little electrical current. This information can be used to report overcurrent faults and undercurrent conditions, such as burnt-out bulbs.For manual control of the loads, an optional MPower 12-Channel Bypass Module (CBMD12) can be installed in conjunction with the CLMD12.Features:
NMEA 2000® Interface
IP67 Rated
Ignition Protected
Opto-isolated from NMEA 2000®, eliminating potential ground loops
Twelve (12) dimmable Electronic Circuit Breakers (ECBs) for On/Off Control over NMEA 2000® network
2 breakers capable of carrying up to 12 Amps
6 breakers capable of carrying up to 10 Amps
4 breakers capable of carrying up to 5 Amps
Individual breaker electrical current monitoring
Breakers can have Power-Up states defined (ON, OFF, or PREVIOUS STATE)
Breakers can be locked against inadvertent actuation.
Seven (7) discrete inputs configurable as Active High or Active Low
Automatic ECB overcurrent shutdown
Automatic ECB thermal shutdown (Overtemperature Protection)
Applications:
Remote control of navigation lights
Remote control of the boarding lights
Burnt-out bulb alerts
Control of area lights with dimming
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Specifications:
AC/DC: DC
Touchscreen: No
Box Dimensions: 4"H x 7"W x 10"L WT: 2.3 lbs
UPC: 873804004181
Quick Guide (pdf)
MPower 12 Channel DC Load Controller Module with NMEA 2K - No ConnectorsDesigned for vessels of all sizes with smaller loads, the MPower® CLMD12 is a compact 12-Channel DC Load Controller Module. Two of the 12 breakers handle a maximum of 12 amps, six handle a maximum of 10 amps, and four handle a maximum of 5 amps, with a total current capacity of 75 Amps. Additionally, circuits can be paralleled.If a smaller circuit needs to be protected, each of the 12 breakers can be set to trip at lower current levels using the new Maretron N2KAnalyzer® V3 software. In addition, the CLMD12 has inputs for up to 7 hard-wired switches that can be used to switch breaker states, or as inputs for other data, such as bilge alarms or hatch positions, etc.The CLMD12 handles many DC load types such as lights, pumps, motors, and electronics. An added benefit of the CLMD12 is that it reports the current through each of the 12 breakers. This allows you to determine if loads are drawing too much or too little electrical current. This information can be used to report overcurrent faults and undercurrent conditions, such as burnt-out bulbs.For manual control of the loads, an optional MPower 12-Channel Bypass Module (CBMD12) can be installed in conjunction with the CLMD12.Features:
NMEA 2000® Interface
IP67 Rated
Ignition Protected
Opto-isolated from NMEA 2000®, eliminating potential ground loops
Twelve (12) dimmable Electronic Circuit Breakers (ECBs) for On/Off Control over NMEA 2000® network
2 breakers capable of carrying up to 12 Amps
6 breakers capable of carrying up to 10 Amps
4 breakers capable of carrying up to 5 Amps
Individual breaker electrical current monitoring
Breakers can have Power-Up states defined (ON, OFF, or PREVIOUS STATE)
Breakers can be locked against inadvertent actuation.
Seven (7) discrete inputs configurable as Active High or Active Low
Automatic ECB overcurrent shutdown
Automatic ECB thermal shutdown (Overtemperature Protection)
Applications:
Remote control of navigation lights
Remote control of boarding lights
Burnt-out bulb alerts
Control of area lights with dimming
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Specifications:
AC/DC: DC
Touchscreen: No
Box Dimensions: 4"H x 7"W x 10"L WT: 1.8 lbs
UPC: 873804004105
Quick Guide (pdf)
MPower® 16-Channel DC Load Controller Module with NMEA 2K without ConnectorsFor larger breakers and more circuits, the MPower® CLMD16 is a 16-Channel DC Load Controller Module. Four of the 16 breakers handle a maximum of 25 amps, and twelve breakers handle a maximum of 12 amps, with a total current capacity of 125 Amps. Additionally, circuits can be paralleled.The CLMD16 also supports two H-Bridge reversing polarity circuits that can be used for loads such as engine hatches, passerelles, trim tabs, etc. The CLMD16 has 8 inputs for hard-wired switches that can be used to switch breaker states, or as inputs for other data, such as bilge alarms or hatch positions, etc. There are 3 inputs capable of monitoring tank levels.The CLMD16 handles many DC load types such as lights, pumps, motors, and electronics. An added benefit of the CLMD16 is that it reports the current through each of the 16 breakers. This allows you to determine if loads are drawing too much or too little electrical current. This information can be used to report overcurrent faults and undercurrent conditions, such as burnt-out bulbs.Features:
NMEA 2000® Interface
IP67 Rated
Ignition Protected
Opto-isolated from NMEA 2000®, eliminating potential ground loops
Sixteen (16) dimmable Electronic Circuit Breakers (ECBs) for On/Off Control over NMEA 2000® network
4 breakers capable of carrying up to 25 Amps
12 breakers capable of carrying up to 12 Amps
Individual breaker electrical current monitoring
Breakers can have Power-Up states defined (ON, OFF, or previous states)
Breakers can be locked against inadvertent actuation.
Capacitive touch switches for local control of all loads
All inputs and outputs are protected against short to Power and short to Ground
Automatic ECB overcurrent shutdown
Automatic ECB thermal shutdown (Overtemperature Protection)
Eight (8) discrete digital input channels capable of sensing +ve or ground signals
Two (2) resistive analog input channels
One (1) 4-20mA current loop input channel
Applications:
Remote control of navigation lights
Remote control of boarding lights
Burnt-out bulb alerts
Control of area lights with dimming
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Quick Guide (pdf)Owner's Manual (pdf)