Newmar 32-12-50 DC Converter [32-12-50]

Description

32-12-50 DC Converter

Convert 20-50 VDC input to 12 VDC negative ground output for powering communication and navigation equipment on negative ground systems. (See Isolated Series for positive ground applications.)

Features:

  • Excellent Regulation: Output voltage maintained within 1% under all line and load conditions within the rating
  • The heat generated by semi-conductors is extracted and dissipated by large heat sink fins that maximize air contact for cool operation and the long life of components
  • Polyurethane conformal coating on PC boards and corrosion-resistant anodized aluminum cases with heavy-duty shock mounts assure survival in hostile environments

Numerous Converter and Load Protection Circuits:

Current limiting

  • Automatic thermal shutdown
  • Short circuit proof
  • Reverse polarity
  • Overvoltage protection
  • Carries CE mark

Specifications:

  • Input Voltage: 20-50
  • Output Voltage: 13.6
  • Output Amps (Intermittent): 50
  • Output Amps (Continuous): 40
  • Case Size (H x W x D): 6.2 x 6.8 x 18.1 inches (15.7 x 17.3 x 46.0 centimeters)
  • Weight: 16 lb. (7.3 kg)
  • Output: 13.6 VDC (internally adjustable 12.6 -14.5) or 24.5 VDC (or specify)
  • Ripple: 150 mV P-P maximum
  • Regulation: 1% Line/Load
  • Switching Frequency: 40 kHz
  • Efficiency: 85% – Typical.
  • Isolation: Output/Chassis; Input/chassis: 250 VDC

Duty Cycle Ratings*:

  • Intermittent: 20 minutes max on time, 20% duty. current limit set at approx. 105% of intermittent rating.
  • Continuous: 24 hours, 100% duty *24-12-3: 2-minute max. on time
  • Idle Current: Less than 100 mA (including power “ON” light)

Operating Temp Specifications:

  • 0-50 degrees C, Derate Linearly From 100% @ 40 degrees C To 50% @ 50 degrees C.
  • Thermal shutdown @ 70 degrees C Case Temperature
  • Model 24-12-3: Full output -25 degrees to +30 degrees C; Derate linearly from 100% @ +30 degrees C to 45% @ +50 degrees C

Mechanical Specifications:

  • Powder-coated aluminum heat sink case
  • Front panel terminal block
  • Heavy-duty mounting flange
  • Conformal coated PC board

Options:

  • Operation as a battery charger or parallel redundant operation* – derate to continuous duty rating (contact factory)
  • Extreme vibration mounting kit. (Information below)

Option: Extreme Vibration Mounting Kit

The Extreme Vibration Mounting Kit is available to protect Newmar power converters from the extreme stresses of shock and vibration when mounted on high-vibration vehicles. The kit replaces the standard vibration kit provided with the unit. It fits into the unit’s mounting flange to act as a ‘super shock absorber’ for electronics in high-vibration applications. It is available to fit all NEWMAR units from 2 to 70 lbs. Specify KIT L for units that weigh 2–15 lbs. and Kit H for 16–7 lbs.

This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns.
Product form

32-12-50 DC ConverterConvert 20-50 VDC input to 12 VDC negative ground output for powering communication and navigation equipment on negative... Read more

SKU: CWR-102306

$1,370.00$1,029.50

    • Price Match Guarantee
    • Free Shipping on orders over $200
    • Secure Checkout

      Description

      32-12-50 DC Converter

      Convert 20-50 VDC input to 12 VDC negative ground output for powering communication and navigation equipment on negative ground systems. (See Isolated Series for positive ground applications.)

      Features:

      • Excellent Regulation: Output voltage maintained within 1% under all line and load conditions within the rating
      • The heat generated by semi-conductors is extracted and dissipated by large heat sink fins that maximize air contact for cool operation and the long life of components
      • Polyurethane conformal coating on PC boards and corrosion-resistant anodized aluminum cases with heavy-duty shock mounts assure survival in hostile environments

      Numerous Converter and Load Protection Circuits:

      Current limiting

      • Automatic thermal shutdown
      • Short circuit proof
      • Reverse polarity
      • Overvoltage protection
      • Carries CE mark

      Specifications:

      • Input Voltage: 20-50
      • Output Voltage: 13.6
      • Output Amps (Intermittent): 50
      • Output Amps (Continuous): 40
      • Case Size (H x W x D): 6.2 x 6.8 x 18.1 inches (15.7 x 17.3 x 46.0 centimeters)
      • Weight: 16 lb. (7.3 kg)
      • Output: 13.6 VDC (internally adjustable 12.6 -14.5) or 24.5 VDC (or specify)
      • Ripple: 150 mV P-P maximum
      • Regulation: 1% Line/Load
      • Switching Frequency: 40 kHz
      • Efficiency: 85% – Typical.
      • Isolation: Output/Chassis; Input/chassis: 250 VDC

      Duty Cycle Ratings*:

      • Intermittent: 20 minutes max on time, 20% duty. current limit set at approx. 105% of intermittent rating.
      • Continuous: 24 hours, 100% duty *24-12-3: 2-minute max. on time
      • Idle Current: Less than 100 mA (including power “ON” light)

      Operating Temp Specifications:

      • 0-50 degrees C, Derate Linearly From 100% @ 40 degrees C To 50% @ 50 degrees C.
      • Thermal shutdown @ 70 degrees C Case Temperature
      • Model 24-12-3: Full output -25 degrees to +30 degrees C; Derate linearly from 100% @ +30 degrees C to 45% @ +50 degrees C

      Mechanical Specifications:

      • Powder-coated aluminum heat sink case
      • Front panel terminal block
      • Heavy-duty mounting flange
      • Conformal coated PC board

      Options:

      • Operation as a battery charger or parallel redundant operation* – derate to continuous duty rating (contact factory)
      • Extreme vibration mounting kit. (Information below)

      Option: Extreme Vibration Mounting Kit

      The Extreme Vibration Mounting Kit is available to protect Newmar power converters from the extreme stresses of shock and vibration when mounted on high-vibration vehicles. The kit replaces the standard vibration kit provided with the unit. It fits into the unit’s mounting flange to act as a ‘super shock absorber’ for electronics in high-vibration applications. It is available to fit all NEWMAR units from 2 to 70 lbs. Specify KIT L for units that weigh 2–15 lbs. and Kit H for 16–7 lbs.

      This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns.

      Recently viewed products

      © 2024 Safe Water, Powered by Safe Water

        • American Express
        • Apple Pay
        • Diners Club
        • Discover
        • Google Pay
        • Mastercard
        • PayPal
        • Shop Pay
        • Visa

        Login

        Forgot your password?

        Don't have an account yet?
        Create account