16/2 AWG Safety Duplex Cable - Flat Cable - Red/Yellow - 100'Duplex Boat Cable is used in low voltage AC applications as well as DC circuits. Pacer manufactures 16 AWG Duplex boat cable in house in the USA for the best quality. First, the cable is built from finely stranded, Type III tinned copper conductors. These conductors allow for flexibility and help to prevent corrosion. The PVC jacket helps 16 AWG Duplex Boat Cable to be flexible while preventing moisture from accumulating. How does it do that? During the extrusion process, the spaces between wires are filled. This leaves no space for moisture or air to accumulate. After that, a talcum powder coating is given to the interior wires. This coating is used to allow the outer jacket to be easily removed. Just another reason 16 AWG Duplex boat cable is perfect for marine use. Pacer's marine wire exceeds the requirements and standards of UL, ABYC, and NMMA.Features:
Extruded exterior cable insulation with no gaps
Highly flexible color coded wire insulation
Stranded, tinned copper conductors
Annealed Finely Stranded Tinned Copper ASTM B172 Class K
Resistant to - Acid, Alkali, Abrasion, Flame, Gasoline, Oil, Moisture
Compliances:
UL Standard - 1426
U.S.C.G - 33 CFR part 183
ABYC - E-11.14
Technical Specifications:
Conductor - Type III annealed finely stranded tinned copper ASTM B172 Class K
Insulation -20 °C to 105 °C flexible, color-coded PVC
Voltage Rating - 600-V
Resistant to - Acid, Alkali, Abrasion, Flame, Gasoline, Oil and Moisture
No. of Conductors - 2
Type of Cable - Duplex
*Sold as an Individual Specifications:
Color: Red/Yellow
Gauge: 16/2 AWG
Length (Feet): 100'
Box Dimensions: 5"H x 7"W x 7"L WT: 5.1 lbs
UPC: 840248200134
Brochure (pdf)
10/2 AWG Duplex Cable - Flat Cable - Red/Black - 100'Duplex Boat Cable is used in low voltage AC applications as well as DC circuits. Pacer manufactures 10 AWG Duplex boat cable in house in the USA for the best quality. First, the cable is built from finely stranded, Type III tinned copper conductors. These conductors allow for flexibility and help to prevent corrosion. The PVC jacket helps 10 AWG Duplex Boat Cable to be flexible while preventing moisture from accumulating. How does it do that? During the extrusion process, the spaces between wires are filled. This leaves no space for moisture or air to accumulate. After that, a talcum powder coating is given to the interior wires. This coating is used to allow the outer jacket to be easily removed. Just another reason 10 AWG Duplex boat cable is perfect for marine use. Pacer's marine wire exceeds the requirements and standards of UL, ABYC, and NMMA.Features:
Extruded exterior cable insulation with no gaps
Highly flexible color coded wire insulation
Stranded, tinned copper conductors
Annealed Finely Stranded Tinned Copper ASTM B172 Class K
Resistant to - Acid, Alkali, Abrasion, Flame, Gasoline, Oil, Moisture
Compliances:
UL Standard - 1426
U.S.C.G - 33 CFR part 183
ABYC - E-11.14
Technical Specifications:
Conductor - Type III annealed finely stranded tinned copper ASTM B172 Class K
Insulation -20 °C to 105 °C flexible, color-coded PVC
Voltage Rating - 600-V
Resistant to - Acid, Alkali, Abrasion, Flame, Gasoline, Oil and Moisture
No. of Conductors - 2
Type of Cable - Duplex
*Sold as an Individual Specifications:
Color: Red/Black
Gauge: 10/2 AWG
Length (Feet): 100'
Box Dimensions: 7"H x 7"W x 7"L WT: 12.5 lbs
UPC: 840248200004
Brochure (pdf)
16/3 AWG Triplex Cable - Black/Green/White - 100' 16 AWG Triplex boat cable is commonly used for AC circuits in boats and recreational vehicles. It is an ideal choice when looking at multiconductor boat cables. Pacer Group manufactures 16 AWG triplex cable in the USA for longevity and easy installation. How is that accomplished? It starts with finely stranded tinned copper conductors. These conductors prevent corrosion and also allow the cable to be flexible. Another important aspect of triplex boat cable is the insulation. The PVC insulation is designed specifically for protection from moisture and fatigue. These conductors also allow the cable to be flexible. Flexibility is essential when working in enclosed marine spaces. The PVC insulation is designed for protection from moisture and fatigue. It is created during the extrusion process. The extrusion process for this cable fills the voids between the conductors. This process eliminates any possibility of moisture or air build up in the wires. To make it even better, talcum powder is coated on the wires. This is done to allow for the easy removal of the jacket during installation. Features:
Stranded, tinned copper
Color coded conductors
Tough PVC Jacket
Highly flexible
Easy to strip and route
Compliances:
UL Standard - 1426
U.S.C.G - 33 CFR part 183
ABYC - E-11.16
Technical Specifications:
Conductor - Annealed Fine Stranded Tinned Copper, ASTM B172 Class K
Insulation -20 °C to 105 °C flexible, color-coded PVC
Voltage Rating - 600-V
Resistant to - Acid, Alkali, Abrasion, Flame, Gasoline, Oil and Moisture
No. of Conductors - 3
Type of Cable - Triplex
Shape of Jacket - Flat
*Sold as an Individual Specifications:
Color: Black/Green/White
Gauge: 16/3 AWG
Length (Feet): 100'
Box Dimensions: 6"H x 7"W x 7"L WT: 7.9 lbs
UPC: 840248200578
Brochure (pdf)
14/2 AWG Duplex Cable - Flat Cable - Red/Black - 100'Duplex Boat Cable is used in low voltage AC applications as well as DC circuits. Pacer manufactures 14 AWG Duplex boat cable in house in the USA for the best quality. First, the cable is built from finely stranded, Type III tinned copper conductors. These conductors allow for flexibility and help to prevent corrosion. The PVC jacket helps 14 AWG Duplex Boat Cable to be flexible while preventing moisture from accumulating. How does it do that? During the extrusion process, the spaces between wires are filled. This leaves no space for moisture or air to accumulate. After that, a talcum powder coating is given to the interior wires. This coating is used to allow the outer jacket to be easily removed. Just another reason 14 AWG Duplex boat cable is perfect for marine use. Pacer's marine wire exceeds the requirements and standards of UL, ABYC, and NMMA.Features:
Extruded exterior cable insulation with no gaps
Highly flexible color coded wire insulation
Stranded, tinned copper conductors
Annealed Finely Stranded Tinned Copper ASTM B172 Class K
Resistant to - Acid, Alkali, Abrasion, Flame, Gasoline, Oil, Moisture
Compliances:
UL Standard - 1426
U.S.C.G - 33 CFR part 183
ABYC - E-11.14
Technical Specifications:
Conductor - Type III annealed finely stranded tinned copper ASTM B172 Class K
Insulation -20 °C to 105 °C flexible, color-coded PVC
Voltage Rating - 600-V
Resistant to - Acid, Alkali, Abrasion, Flame, Gasoline, Oil and Moisture
No. of Conductors - 2
Type of Cable - Duplex
*Sold as an Individual Specifications:
Color: Red/Black
Gauge: 14/2 AWG
Length (Feet): 100'
Box Dimensions: 5"H x 7"W x 7"L WT: 6.95 lbs
UPC: 840248200202
Brochure (pdf)
ST Blade Compact Fuse Blocks - 4 Circuits w/CoverProvides surface mount circuit protection for ATO®/ATC® Fuses in a compact footprint. The single side design allows wire entry from one side to maximize space.
Compact common source fuse block
Accepts ATO® and ATC® fast acting blade fuses
Single side entry wiring
Ignition Protected-meets ISO 8846 and SAE J1171 for use in a gasoline engine compartment
Insulating cover meets ABYC/USCG insulation requirements
Tin-plated copper buses and fuse clips
Accepts ring or snap fork type terminals
Small format standard and custom labels available
Specifications
Circuits:4
Maximum Amperage: 100A per block / 30A per circuit
Maximum Voltage:32V DC
Mounting: #8 Screw (M4)
Screw Terminal Torque:#8-32 Screws with captive star lock washer in-lb (0 Nm)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Fuse Type: ATO/ATC
Type: Fuse Blocks
Box Dimensions: 2"H x 3"W x 8"L WT: 0.5 lbs
UPC: 632085050450
ATD Automatic Timer DisconnectAdjustable time or voltage based battery disconnect automatically shuts off devices to preserve battery power
12V signal triggers relay to connect battery power to devices. When signal is removed the timer is activated and will disconnect devices after a preset time
Disconnect can be triggered based on time, low voltage, or removal of 12V signal
Low voltage will disconnect if time hasn_t been reached to preserve battery power
Time and voltage options can be turned off to allow 12V signal based disconnect
Clip-on cover insulates terminal connections
One-piece stainless flange nuts ensure safe and secure connections
Integrated LED indicates status
Specifications:
Nominal Voltage:12V DC
Amperage Operating Current: 175mA(Combine / 15mA(Open)
Continuous Rating:120A
Intermittent Duty: 210
Terminal Stud Size: 3/8"-16 (M10)
Time Range: 15min-4hrs
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Owner's Manual (pdf)
Side Entry CableClam w/Stainless Steel Dress CapProvides a waterproof side entry for antenna cables without requiring removal of the factory installed connector. Stainless steel dress cap conceals mounting hardware and matches stainless steel deck fittings.Features:
Simple one-piece design for easy side mount installations
Low profile, contoured edge reduces the risk of tangling lines
A polished stainless steel dress cap conceals mounting hardware, matches other deck hardware and offers protection from UV
Includes all fasteners
For use above the waterline only
Specifications:
Max Cable Diameter: 0.28in (7.11 mm)
Max Connector Diameter: 1in (25.4 mm)
Dress Cap Material: 316 Stainless Steel
Ring Material: UV-Stabilized Thermoplastic
Seal Material: UV-Stabilized Buna-N Rubber
Weight: 0.50lb (0.23 kg)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Type: Deck Seal
Box Dimensions: 1"H x 4"W x 8"L WT: 0.2 lbs
UPC: 632085100711
Quick Guide (pdf)
120/240v AC Main(1) 50A C-Series Toggle 3 Pole MainFeatures:
Red reverse polarity indicating LED
All neutral and safety ground buses installed
Label backlighting pre-installed
All LEDs installed
Maximum panel Amperage - 50 Amperes
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Max Breaker Quantity: 1
AC/DC: AC
Voltage: 120/240v
Box Dimensions: 5"H x 6"W x 9"L WT: 1.4 lbs
UPC: 632085073725
Quick Guide (pdf)
2107 PowerBar 600AMP Cable Connector - 8 x 3/8" 16 Stud TerminalSpecifications:
Maximum Voltage: 300 V AC/48V DC
Number of Terminal Studs: 8
Terminal Type: 3/8" - 16 Stud
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
4215Square Format Label Set30 Black DC Labels
30 common DC labels
Included with WeatherDeck Waterproof Panels
Reinforced, weatherproof material
Used on WeatherDeck Waterproof Panels
Used on Battery Management Panels
Used on 360 Panel System
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
XD Flex 2 Dual VSR/Relay with Knob - Tinned WiresFeatures:
500 Amp Continuous Capability Per Relay / Extremely Compact Footprint
Available With or Without Intuitive Front Facing Manual Override Knobs with the ability to Lock Relays ON or OFF for Servicing
Flexible Functionality via Dip Switches, utilize each as a Relay/Battery Disconnect, Voltage Sensing Relay, or Low Voltage Disconnect
Improved Alternative Replacement to Legacy Remote Switching Solutions.
Remote ON/OFF/Auto Inputs Allow Forced Close or Open or Allow Automatic Operation Based on Voltage Sensing
Local and Remote LED Indicators Per Relay
Mechanical Only Contactor Options
Specifications:
Type: Electric
Box Dimensions: 3"H x 6"W x 7"L WT: 1.89 lbs
UPC: 850053879333
Brochure (pdf)
A Series Black Toggle Panel Mount Circuit Breaker - Single Pole 15AFeatures:
Easily Mounts In Standard Panels, accepting A-Series and C-Series magnetic-hydraulic circuit breakers. Includes mounting screws.
AC & DC Rated to cover a wide range of system application needs.
Toggle-Style Actuator for easy on/off switching control, combined with circuit protection.
High Voltage Rating easily supports 12 and 24 Vdc applications while offering advanced protection for 36 and 48 Vdc applications.
High Electrical / Manual Switching Endurance delivers 6,000 cycles at full current.
High Interrupt Current safely protects circuits connected to large paralleled battery banks with significant available power.
Toggle Guard and Panel Plug accessories pair with A-Series breakers to protect against accidental switching and fill unused panel slots.
Specifications:
Amperage: 15a
Type: Electric
Box Dimensions: 2"H x 4"W x 4"L WT: 0.2 lbs
UPC: 850067590941