Electrical

3871 products


  • Sale -15% Analytic Systems AC Charger 2-Bank 40A, 24V Out, 110VAC In CSA/UL [BCA1000-110-24]

    Analytic Systems AC Charger 2-Bank 40A, 24V Out, 110VAC In CSA/UL [BCA1000-110-24]

    AC Charger 2-Bank 40A, 24V Out, 110VAC In CSA/ULThis BCA1000 COTS AC-source battery charger is designed to charge a battery at 24VDC.Internally, the single-board design incorporates a time-tested switch mode technology for unmatched efficiency and ultra-quiet operation. Additional stages of filtering on the outputs reduce conducted and radiated EMI noise to very low levels.This unit features a user-selectable 2-stage or 3-stage charging profile, and the output voltage adjusts for optimum charging. Additionally, the equalization mode and voltage temperature compensation increase the lifetime of expensive battery systems.Built for rugged duty, this unit is constructed from heavy-duty anodized extruded and billet machined aluminum with O-ring seals and all stainless-steel fasteners.Reliability features of this product line include LED status indicators, over-temperature shutdown, current limiting, reverse polarity battery connection protection, output short circuit shutdown with automatic recovery, and output over-voltage protection.Features: Adjustable charging voltage Single or two-bank charging Ultra-quiet low EMI operation Bright LED indicators Equalize mode functionality Rugged and reliable Specifications:Input: Nominal Voltage: 110 VAC  Actual Voltage: 90-133 VAC Frequency: 45-65 Input Amps (Max): 13 A  Input Fuse (Slow blow): MDA-20 Output: Nominal Voltage: 24 VDC Float Voltage: 27.2 VDC Absorption Voltage: 28.8 VDC Charging Amps: 40 A  Output Fuses (parallel): 2x ATC-30  Absorption to Float Switch: 6 Amps Output Overvoltage Protection: 32 ± 1V  Temperature Compensation: -60mV/°C  Equalize Voltage: 31.0 VDC  Recommended Battery Size (Amp-hours): 160-240  Supported no. of Battery Banks: Charges up to two connected battery banks Output Volt. Adjust: +/- 1.0 V Charging Stages (Selectable): 2 Stage (CC-Float) or 3 Stage (CC-Absorption-Float), User-selectable Output Ripple & Noise: <50 mV Transient Response: <1V for 50% Surge Regulation (Line & Load): < +/- 0.5% Duty Cycle: Continuous (100% for 24 hours per day) Efficiency: >75% @ Maximum Output Mechanical: Length: 14.5 in. / 36.8 cm Width: 9.9 in. / 25.1 cm Height: 5.0 in. / 12.7 cm Clearance: 1.0 in. / 2.5 cm all around Weight: 12.0 lb. / 5.5 kg (approximate) Material and Finish: Black anodized marine-grade aluminum Fasteners: 18-8 stainless steel Input Connection: 3 m / 9.8ft 3xAWG14 power cord with NEMA 5-15 or CEE 7/VII compatible plug Output Connection: Molex 4-pin BEAU Terminal Strip Battery Temperature Sensor Connection: RJ45 ‘telephone jack’ connector Environmental & Safety: Operating Temperature: -25°C to +40°C @ maximum output. Derate linearly 2.5% per °C from +40°C Storage Temperature: -40°C to +100°C Humidity: 0 - 95% relative humidity (non-condensing) with standard conformal coating Isolation: Input-Output & Input-Case: 1500 VDC; Output-Case: 500 VDC (1500 VDC @ 48 V Out) Cooling: Two interior thermostatic cooling fans Audible Noise: 0 dB @ 1 meter when the fan operating Typical Service Life: > 10 years (87,600 hrs.) Warranty: Three Years of Parts and Labor Safety: Designed to meet UL458 & CSA 22.2.107.1 This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Specifications: Charging Banks: 2 Box Dimensions: 7"H x 12"W x 16"L WT: 12.6 lbs Brochure (pdf)

    $1,357.00$1,153.50

  • Sale -15% Analytic Systems AC Charger 2-Bank 70A, 12V Out, 85-264VAC In Power-Factor Correction [BCA1050-12]

    Analytic Systems AC Charger 2-Bank 70A, 12V Out, 85-264VAC In Power-Factor Correction [BCA1050-12]

    AC Charger 2-Bank 70A, 12V Out, 85-264VAC In Power-Factor CorrectionThe BCA1050 Series battery charger provides up to 1000 watts of charging power to a one- or two-bank battery system at 12, 24, 32, 36, 48, or 72 (rail) VDC from an 85 – 264 VAC source.The BCA1050 Series chargers (BCA) and power supplies (PWS) are designed to supply a DC load or charge a battery at 12, 24, 32, 36, 48, or 72 (rail) VDC. The 1050 family provides up to 1000 watts of precision power, while the 1550 family can supply up to 1550 watts. These 1050 and 1550 families are identical to their previous models (1005 and 1505, respectively) in form, fit, and function as a direct drop-in replacement.Internally, the recently updated design incorporates a Power Factor Corrected (PFC) input stage. The PFC input stage increases efficiency over the previous auto-switching technology. It eliminates the dead spot between 110 and 220 VAC input, allowing the power supply to run continuously from 85 to 264 VAC at 45 to 65 Hz. Heavy input and output filtering also reduce EMI to deficient levels to prevent radio interference. Extra features include visual indicators for low input voltage, charging, and overtemperature.Features: Power Factor Corrected AC Input Fast and accurate charging Can function as a power supply Visual indicators for operation and errors Five-year parts and labor warranty Specifications: Function: Battery charger Conversion: AC to DC Power Level: 1000 Input Volts: 85 – 264 VAC, 110 VAC, 110/220 VAC, 220 VAC Power Factor Corrected (PFC): Yes Output Volts: 12 VDC Output Amps Continuous: 80 Input/Output Isolation: Yes Technology: Analog Charging Stages: 3 Temperature Compensation: Yes Equalize: Yes Battery Banks: 2 Product Series on the website: BCA1050 Options Codes: 'Z' No Conformal Coating (Any Model), 'V' Digital Volt/Ammeter, 'U' Safety Special Inspection (CSA/UL), 'P' Portable (Handle & Feet), 'M' Military Rugged, 'E' European ROHS compliant This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Specifications: Charging Banks: 2 Box Dimensions: 9"H x 10"W x 22"L WT: 20 lbs

    $1,587.00$1,349.50

  • Sale -35% Blue Sea 3116 - SMS Panel Enclosure w/ELCI (30A) and 3 Blanks - 120V [3116]

    Blue Sea 3116 - SMS Panel Enclosure w/ELCI (30A) and 3 Blanks - 120V [3116]

    3116 - SMS Panel Enclosure with ELCI (30A) and 3 Blanks - 120VThe 3116 panel enclosure is built for Equipment Leakage Circuit Interrupters (ELCI) main circuit breakers and other large frame devices.  Meets ABYC E-11 when used with an ELCI Main circuit breaker and mounted within 10' of AC shore power inlet.Features: Blank apertures for custom breaker loading  Glass filled polycarbonate base Clear cover allows easy view of circuit breaker status Overlapping cover for strength and increased gasket protection Oversized, formed in place seamless PUR gasket Easily removable stainless steel hinge pin for unobstructed installation Stainless steel latch secures cover without penetrating the enclosure Blank circuit positions accommodate Carling Technologies™ A and C Series Flat Rocker and ELCI Main circuit breakers Includes waterproof glands LED lights for back lighting and ON indication Technical Specifications: Circuit Breaker Type - 1 x ELCI (30A) Main 120V and 3 x Blank Dimensions (Overall) (H x W x D) - 7.6" x 7.4"" x 4.7" (192 x 188 x 120mm) Dimensions  (Enclosure) (H x W x D) - 6" x 6" x 4" (152 x 152 x 102mm) LEDs Installed - 1 x Red (Reverse Polarity - 120V AC and 4 x Green ON (120V AC) In the Box: 3116 Enclosure Glands x 5 Labels Mounting hardware Instruction manual *Sold as an Individual WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Quick Guide (pdf)Brochure (pdf)

    $690.02$451.50

  • Sale -23% Paneltronics 'A' Frame Magnetic Circuit Breaker - 25 Amps - Double Pole [206-082S]

    Paneltronics 'A' Frame Magnetic Circuit Breaker - 25 Amps - Double Pole [206-082S]

    "A" Frame Magnetic Circuit Breakers 25 AmpDouble Pole Standard branch AC or DC circuit breaker for Paneltronics electrical distribution panels Meets all American Boat and Yacht Council (ABYC) Standards for non ignition protected circuit breaker UL Recognized (UL 1077) for use in the U.S.A., and CSA Certified for use in Canada (ABYC E-11.12.2.8. Trip free (ABYC E-11.12.1.7.2.2. and E-11.12.2.8.1.) Manual reset (ABYC E-11.12.1.7.2.4. and E-11.12.2.8.1.) Specifications: Amperage: 25a Box Dimensions: 2"H x 2"W x 3"L WT: 0.3 lbs UPC: 602290200247

    $36.95$28.50

  • Sale -42% Blue Sea 8076 AC Main +11 Positions Toggle Circuit Breaker Panel - White Switches [8076]

    Blue Sea 8076 AC Main +11 Positions Toggle Circuit Breaker Panel - White Switches [8076]

    8076 AC Main +11 Positions Toggle Circuit Breaker Panel - White SwitchesFeatures: Red reverse polarity indicating LED All hot, neutral and safety ground buses installed, fully pre-wired All circuit label positions are backlit on standard panels - No kit required "ON" indicating LEDs installed in all circuit positions Specifications: Positions: 11 Nominal Voltage: 120v AC Height: 7.5" Width: 10.5" Included: (1) 8031 Basic AC Panel Label Set - 30 Labels (12) 8034 LED - 120v AC Green (1) 8066 LED - 120v AC Red (8) 7210 A-Series White Toggle Circuit Breaker - Single Pole 15A (Branch) (1) 7238 A-Series White Toggle Circuit Breaker - Double Pole 30A (Main) (1) 8244 AC Micro Voltmeter - 0 to 150v AC (Meter) (1) 8246 AC Micro Ammeter - 0 to 50A w/ Coil (Meter) WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications: AC/DC: AC Max Breaker Quantity: 11 Voltage: 120v Box Dimensions: 5"H x 10"W x 13"L WT: 4.1 lbs UPC: 632085080761 Owner's Manual (pdf)

    $844.97$492.50

  • Sale -23% Newmar ERC-12-35 Emergency Relay [ERC-12-35]

    Newmar ERC-12-35 Emergency Relay [ERC-12-35]

    ERC-12-35 Emergency RelayThe Emergency Relay/Charger is a device for assuring immediate backup power to communications equipment in the event AC power is temporarily lost to the power supply or the supply fails. In addition, it will allow the power supply to act as a “trickle” battery charger without any additional modification.When the ERC senses a loss of DC voltage, it employs a fast-acting S.P.D.T. relay to automatically switch the equipment’s DC input over to a standby battery to allow continued operation. When the power supply is returned to service, the ERC disengages the battery and puts the supply back online to provide DC voltage. While the power supply is operating normally, a small portion of the output current is directed to the battery to trickle-charge and maintain it at full voltage. (Note: Battery float voltage will be maintained at .7 volts lower than the power supply voltage.)Note: If the power supply is down for an extended period, the backup battery may become significantly discharged while powering the radio. When the supply returns to service, the trickle charge rate of the ERC may be insufficient to restore the battery to full charge promptly. In the event this occurs, a supplemental charger may be necessary to bring the battery to full charge.InstallationSelect a suitable location as close to the battery as possible where there is no likelihood of accidental contact and shorting of the terminals. The ERC may be mounted vertically, horizontally, or even upside-down, if necessary, without affecting its operation. Two # 10 sheet metal or wood screws will be needed. Mounting on a metal surface is acceptable as the inputs and outputs are isolated from the mounting bracket.Note: If the battery is stored in an unventilated enclosure, users are not recommended to mount the ERC within the same enclosure. As with any relay, it should not be in an area where there may be battery gases or any other potentially explosive gases present.WiringThe wiring should be as direct as possible. Ensure that the battery posts are free from corrosion. Determine the correct gauge wire using the information below. The wire length is the total length of the run (ERC-to-Radio + Power Supply-to-ERC) or (ERC-to-Radio + Battery-to-ERC), whichever is longer. 5 ft. wire length = #8 AWG 10 ft. wire length = #6 AWG 15 ft. wire length = #4 AWG 20 ft. wire length = #4 AWG Use the provided crimp ring lug connectors to secure wiring to the ERC. Models ERC-12-15 and ERC-24-15 have yellow plastic terminal covers, which must be reinstalled after wiring to prevent accidental shorting.Specifications: Input Range: 10.0-14.5 VDC (12V) Relay Rating: 30 amps continuous & 35 amps intermittent Float Trickle (typical): 0.1 amps Dimensions (inch): 5-1/8" x 2-7/8" x 3-5/8" Weight: 1.15 lbs Owner's Manual (pdf)

    $281.00$216.50

  • Sale -39% Blue Sea 7410 A-Series Flat Rocker Circuit Breaker - Double Pole - 10A [7410]

    Blue Sea 7410 A-Series Flat Rocker Circuit Breaker - Double Pole - 10A [7410]

    A-Series Flat Rocker Circuit Breaker - Double Pole - 10AFeatures: Color actuator indicates "OFF" position "Trip Free" design cannot be held "ON" during fault current condition International ON/OFF symbols support vertical or horizontal mounting Specifications: Amperaget: 10A AC / 10A DC Actuator Style: Flat Rocker Poles: 2 Maximum Voltage: 120V AC / 240V AC / 32V DC Circuit Breaker Type: Magnetic Hydraulic - trip free Interrupt Capacity: 3000A @ 240V AC / 1500A @ 240V AC[TUV] / 5000A @ 32V DC Minimum Operating Temperature: -40° C Maximum Operating Temperature: 85° C Mounting Screw: #6-32 Stainless Steel Mounting Screw Torque: t6 in-lb (0.68 Nm) Screw Terminal Torque: 14 in-lb (1.58 Nm) Switching Cycles: 10000 Terminal Screw: #10-32 Stainless Steel Weight: 0.38lb (0.17 kg) WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications: Amperage: 10a Box Dimensions: 2"H x 3"W x 4"L WT: 0.4 lbs UPC: 632085074104

    $61.25$37.50

  • Sale -29% Blue Sea 1525 360 Panel - M2 Monitor Panel Blank [1525]

    Blue Sea 1525 360 Panel - M2 Monitor Panel Blank [1525]

    360 Panel - M2 Monitor Panel Blank1 x 1 360 Panel System module mounts any M2 Monitor and matches existing 360 panelsWARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Owner's Manual (pdf)

    $57.23$40.50

  • Sale -34% Blue Sea 7271 300A C-Series Triple Pole Toggle DC Circuit Breaker [7271] Blue Sea 7271 300A C-Series Triple Pole Toggle DC Circuit Breaker [7271]

    Blue Sea 7271 300A C-Series Triple Pole Toggle DC Circuit Breaker [7271]

    C-Series Toggle DC Double PolePN: 7271Poles: 3Color: WhiteAmperage: 300AFeatures: Provides overcurrent protection for inverters, bow thrusters, and windlasses Combines switching and circuit protection into a single device "Trip Free" - cannot be held closed after trip WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications: Amperage: 300a Box Dimensions: 3"H x 3"W x 4"L WT: 0.3 lbs UPC: 632085072711

    $197.59$129.50

  • Blue Sea 8089 C-Series Plug Panel Kit [8089]

    Blue Sea 8089 C-Series Plug Panel Kit [8089]

    Panel Plug Kit Includes circuit breaker mounting screws, C-Series panel plug, LED plug and blank label Designed for C-Series Circuit Breakers Heavy 1/8" aluminum 5052 Alloy Two-part polyurethane slate gray finish Accepts standard Blue Sea Systems' backlight labels Accepts standard Blue Sea Systems' "ON" indication LEDs WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.

    $8.50

  • Sale -18% Scanstrut Flip Pro 12V Power Socket [SC-12V-F1] Scanstrut Flip Pro 12V Power Socket [SC-12V-F1]

    Scanstrut Flip Pro 12V Power Socket [SC-12V-F1]

    Flip Pro 12V Power SocketFlip Pro 12V Power Socket takes onboard power delivery to a new level, featuring a IPX4 spring loaded lid, and an impressive 150W max power on a 12V system.  When not in use, the spring-loaded cap remains tightly closed, protecting the socket from the elements. When in use, it quickly locks open to protect your cables when plugged in.Features: 120 -150W max power 12V system only IPX4 waterproof Compact footprint Marine-grade materials Nickel-Plated copper alloy internal contacts UV resistant 316 stainless hinge and springs UniversalFits all 12V power socketsInstallationEasy Install, using a standard Ø32mm (1.25”) hole sawElectrical InformationRed LED running light Brochure (pdf)

    $24.99$20.50

  • Sale -34% Blue Sea 9012 L Solenoid Switch - 12-24VDC - 250A [9012]

    Blue Sea 9012 L Solenoid Switch - 12-24VDC - 250A [9012]

    L Solenoid Switch - 12-24VDC - 250AFeatures: Hermetically sealed contacts / vaporproof Ignition protected - safe for installation aboard gasoline powered boats Activated by an ON-OFF switch mounted anywhere Integrated coil control minimizes heating and amperage draw 450 Amp Class Designed for 12 or 24 Volt systems Ignition protected -- safe for installation aboard gasoline-powered boats Activated by a low amperage ON-OFF switch mounted anywhere Specifications: Control Circuit Connection: 20 AWG Tinned Wire Nominal Voltage: 12V DC / 24V DC Coil Function: Normally Open Mounting: #10 Operating Amperage Current: 3.6A when changing state Amperage Operating Current: 0.13A @ 12 V / 0.07A @ 24 V Terminal Stud Torque: 90 in-lb (10.17 Nm) Continuous Rating: 250A Using 1/0 Wire Size / 300A Using 2/0 Wire Size / 400A Using 4/0 Wire Size / 450A Using 2 x (2/0) Wire Size Intermittent Rating: 275A (5 min) Using 1/0 Wire Size / 400A (5 min) Using 2/0 Wire Size / 500A (5 min) Using 4/0 Wire Size / 600A (5 min) Using 2 x (2/0) Wire Size Cranking Rating 30 sec: 1,000A / 1000A DC Contact Form: SPST-NO Input Voltage: 9-36V DC Inrush Rating: 0.25 sec (10 repeats): 2000A Switching Cycles: 1,000,000 Terminal Stud: Serrated Flange Nut Terminal Stud Length: 0.66" (16.76mm) Terminal Stud Size: 5/16" (M8) Weight: 1.00lb (0.45 kg) WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications: Continuous Amperage: 450a Box Dimensions: 3"H x 4"W x 7"L WT: 1 lbs UPC: 632085090128 Owner's Manual (pdf)

    $275.09$180.50

Electrical

© 2024 Safe Water, Powered by Safe Water

    • American Express
    • Apple Pay
    • Diners Club
    • Discover
    • Google Pay
    • Mastercard
    • PayPal
    • Shop Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account