45-Series Combo Carbon Monoxide Propane Alarm Surface Mount - BlackHave a safe TRIP!Test and inspect the Propane and CO alarms installed in your RV every week and replace malfunctioning alarms.Replace all Propane and CO alarms that are 5 years old or older.Install alarms listed for RV use.Prevent accidents by teaching family and friends about the operation of the alarms. Never ignore a sounding alarm.Features:
Double-duty alarm - Detects both gas leaks and CO gas simultaneously
Reliable - 12V power means no missing or dead batteries to replace
Durable - Built for the extreme RV environment
Approved - Meets RVIA/NFPA requirements
End of Life Signal
Specifications:
Voltage - Input Range (Volts): 12v
Generator Shutdown: No
Fume Type: Carbon Monoxide
Box Dimensions: 2"H x 8"W x 10"L WT: 0.4 lbs
UPC: 715456457437
30 Series 12V RV Propane Alarm - BlackMeets requirements set by RVIA for LP Gas Alarms on RVs. Test/Reset Button - Mute alarm during ventilation. Tests all detector functions with 1 touch. No dangerous gas is required. The alarm is fully operational during the mute cycle and will re-alarm if hazardous conditions recur. Built for the extreme RV environment. UL listed for RVs and Unconditioned Areas.Specifications:
Size: 6-3/8 in. W x 2-7/8 in. H x 1 in. D
1-year limited warranty
Flush mount
12-Volt
Color: Black
Specifications:
Voltage - Input Range (Volts): 12V
Box Dimensions: 2"H x 8"W x 10"L WT: 0.45 lbs
UPC: 715456404332
Fixed Heat Detector with BaseThe Fireboy-Xintex Heat Detector uses a single thermistor to sense the air temperature around the detector. This heat detector was designed to detect how fast the temperature is increasing.Features:
163°F Fixed Heat Detector
Housing: White flame-retardant polycarbonate
Terminals: Nickel-plated stainless steel
Ideal in environments that are dirty or smoky
Unaffected by wind or atmospheric pressure
Remote test feature
Specifications:
Detection Principle: Measurement of heat using a thermistor
Sampling Frequency: Once every four seconds
Supply Voltage: 8.5 V dc to 33 V dc
Supply Wiring: Two wire supply, polarity sensitive
Power-up Time: < 20 seconds
Minimum: ‘detector active’ voltage: 6 V
Holding Voltage: 5 V - 33 V
Minimum Holding Current: 8 mA
Minimum Voltage to Light Alarm LED: 5 V
Alarm Reset Voltage: < 1 V
Alarm Reset Time: One second
Alarm Indicator: Integral indicator with 360º visibility
Operating & Storage Temperature: -40ºC to +70ºC
Operation:
Open-web casing that enables air to flow freely across a thermistor which measures the air temperature every two seconds
A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit - the alarm level - has been reached
Detectors the microprocessor uses algorithms to determine how fast the temperature is increasing
Two Zone Detection & Alarm Panel - 2-5/8" Display - 12/24V DCEach system consists of a monitor panel and up to 14 smoke or heat detectors and/or rate of rise heat detectors connected to each zone (sold separately.)Features:
Visual and audible indications of a fire or fault
Water resistant display
Voltage and EMI protected
Reverse polarity protected
Specifications:
Supply Voltage: 9-32V DC
Zone Loop Voltage: 24V DC (regardless of input voltage)
Minimum Alarm Current: 15mA
Maximum Current Per Zone: 400mA
Maximum Sensors Per Zone: 8
EOL Resistor: 5.6kΩ
Potential Free Transistor Output (Fault, Alarm): 50V max
Relay Output (Buzzer): 2A
Owner's Manual (pdf)
CO Alarm Internal Battery - BlackA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features:
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD Internal battery model uses included maintenance-free lithium-metal batteries. No wiring and reduced labor and material costs to install.
Technical Specifications:
Power Usage - None
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - No
*Sold as an Individual Specifications:
Blower Relay: No
Fume Type: Carbon Monoxide
Generator Shutdown: No
Sensors Included: 1
Voltage - Input Range (Volts): N/A
Box Dimensions: 2"H x 4"W x 5"L WT: 0.35 lbs
UPC: 619749208563
Owner's Manual (pdf)Brochure (pdf)
Combo Carbon Monoxide Propane Alarm Surface Mount - WhiteHave a safe TRIP!Test and inspect the Propane and CO alarms installed in your RV every week and replace malfunctioning alarms.Replace all Propane and CO alarms that are 5 years old or older.Install alarms listed for RV use.Prevent accidents by teaching family and friends about the operation of the alarms. Never ignore a sounding alarm.Features:
Double-duty alarm - Detects both gas leaks and CO gas simultaneously
Reliable - 12V power means no missing or dead batteries to replace
Durable - Built for the extreme RV environment
Approved - Meets RVIA/NFPA requirements
End of Life Signal
Specifications:
Generator Shutdown: No
Fume Type: Carbon Monoxide
Voltage - Input Range (Volts): 12v
Box Dimensions: 2"H x 8"W x 10"L WT: 0.45 lbs
UPC: 715456357416
SMI100RV Smoke Detector 9V Battery PoweredAn ideal pocket-sized reference book for comprehending maritime flags. This guide is both comprehensive and concise, encompassing: Early detection of smoke and fire emissions to avert personal injury with the SMI100RV Boat and RV Approved Battery-Operated Smoke Alarm, which is sanctioned for use in boats and recreational vehicles, adhering to the latest industry standards. The detector has a hinged cover for effortless battery replacements, while the tamper-resistant locking pin prevents premature battery removal.Features:
Detect Smoke and Fire Emissions Early to Prevent Personal Injury With Model SMI100RV
Compact Design: 5.58" Diameter x 1.99" Height
Fast & Easy Installation
9V Battery Powered, No Wiring Required
Low Battery Indicator
Silence Feature
Test Button Easily Accessible on the Cover of the Alarm
Alarm Horn: 85 dB @ 10 ft
Smoke Sensor: Ionization
Listed to UL217 for RV Use Eighth Edition
Complies with U.S. Coast Guard Sect. 28.325(b)
Package Contents:
Smoke Alarm
9-Volt Battery
Specifications:
Blower Relay: No
Fume Type: Smoke
Generator Shutdown: No
Voltage - Input Range (Volts): 9
Box Dimensions: 2"H x 6"W x 6"L WT: 0.6 lbs
UPC: 619749321538
CO Alarm Internal Battery - WhiteA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features:
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD Internal battery model uses included maintenance-free lithium-metal batteries. No wiring and reduced labor and material costs to install.
Technical Specifications:
Power Usage - None
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - No
*Sold as an Individual Specifications:
Blower Relay: No
Fume Type: Carbon Monoxide
Generator Shutdown: No
Sensors Included: 1
Voltage - Input Range (Volts): N/A
Box Dimensions: 2"H x 4"W x 4"L WT: 1 lbs
UPC: 619749208662
Owner's Manual (pdf)Brochure (pdf)
CO Alarm 12/24V DC - BlackA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features:
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD 12/24V DC model uses boat power and has permanent internal backup Lithium-metal batteries
Technical Specifications:
Power Usage - 4 mA
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - No
*Sold as an Individual Specifications:
Blower Relay: No
Fume Type: Carbon Monoxide
Generator Shutdown: No
Sensors Included: 1
Voltage - Input Range (Volts): 12 - 24
Box Dimensions: 2"H x 4"W x 6"L WT: 0.4 lbs
UPC: 619749208723
Owner's Manual (pdf)Brochure (pdf)
CO Alarm 12/24V DC with Interconnect - WhiteA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features:
Interconnect up to ten (10) CO alarms - all connected CO alarms sound together
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD 12/24V DC model uses boat power and has permanent internal backup Lithium-metal batteries
Technical Specifications:
Power Usage - 4 mA
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - Yes
*Sold as an Individual Specifications:
Blower Relay: No
Fume Type: Carbon Monoxide
Generator Shutdown: No
Sensors Included: 1
Voltage - Input Range (Volts): 12 - 24
Box Dimensions: 2"H x 4"W x 6"L WT: 0.4 lbs
UPC: 619749208853
Owner's Manual (pdf)Brochure (pdf)
Propane Fume Detector w/Automatic Shut-Off & Plastic Sensor - No Solenoid Valve - Black Bezel DisplayDetect propane leaks early and automatically shut off gas supply to prevent personal injury and possible explosions.Features/Specifications:
2-3/16" Round Black Display with LEDs & Silence/Test Button
68 dBA Alarm will sound & Red LED will light at 20% of the LEL
Simple Installation
9-30VDC
Operating Temperature: -40°F to 185°F (-40°C to 85°C)
Reverse Polarity Protected
Current Draw @ 12VDC: Nominal:55mA / Maximum:95mA
Specifications:
Blower Relay: No
Fume Type: Propane
Generator Shutdown: No
Sensors Included: 1
Voltage - Input Range (Volts): 9-30v
Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs
UPC: 619749207443
62 Series Carbon Monoxide Alarm w/Relay - 12V - 62-542-R-Marine - Flush Mount - BlackMini Carbon Monoxide Alarm with a compact space saving design that replaces your CO alarms that are over 5 years old! The 62-542-R-Marine includes a normally closed relay. Used to turn on exhaust fans, remotes, horns, lights, signals or connect to alarm systems.Features:
Space Saving
Compact design for boats
Flush Mount
Designed for the harsh marine environment
No False Alarms due to new boat smell, outgassing or non-hazardous levels of hydrocarbon gases encountered while boating
Advanced Technology - Alarm Mute button silences alarm while boat is ventilated
Rapid recovery sensor resets when silenced or reactivates alarm if dangerous levels of CO remain
Reliable - 12 Volt power means no missing or dead batteries to replace
Memory Scan™- Retains the CO level that activated the alarm. After ventilation, it is impossible to know what the CO level was unless your detector has memory
Micro Current Technology - Saves precious battery power in a boat62-541-R-Marine and 62-542-R-Marine include normally closed relay
Use to turn on exhaust fans, remote horns/lights/signals or connect to alarms systems
Listed to UL 2034 Marine Use and CSA 6.19-01
Specifications:
Fume Type: Carbon Monoxide
Generator Shutdown: No
Voltage - Input Range (Volts): 12v
Box Dimensions: 2"H x 8"W x 10"L WT: 0.5 lbs
UPC: 715456625492