CO Alarm Internal Battery w/Interconnect - WhiteA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features:
Interconnect up to ten (10) CO alarms - all connected CO alarms sound together
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD Internal battery model uses included maintenance-free lithium-metal batteries. No wiring and reduced labor and material costs to install.
Technical Specifications:
Power Usage - None
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - Yes
*Sold as an Individual Specifications:
Blower Relay: No
Fume Type: Carbon Monoxide
Generator Shutdown: No
Sensors Included: 1
Voltage - Input Range (Volts): N/A
Box Dimensions: 2"H x 4"W x 6"L WT: 0.4 lbs
UPC: 619749208693
Owner's Manual (pdf)Brochure (pdf)
CO Alarm 12/24V DC - WhiteA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features:
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD 12/24V DC model uses boat power and has permanent internal backup Lithium-metal batteries
Technical Specifications:
Power Usage - 4 mA
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - No
*Sold as an Individual Specifications:
Blower Relay: No
Fume Type: Carbon Monoxide
Generator Shutdown: No
Sensors Included: 1
Voltage - Input Range (Volts): 12 - 24
Box Dimensions: 2"H x 4"W x 4"L WT: 1 lbs
UPC: 619749208822
Owner's Manual (pdf)Brochure (pdf)
30 Series 12V RV Propane Alarm - WhiteMeets requirements set by RVIA for LP Gas Alarms on RVs. Test/Reset Button - Mute alarm during ventilation. Tests all detector functions with 1 touch. No dangerous gas is required. The alarm is fully operational during the mute cycle and will re-alarm if hazardous conditions recur. Built for the extreme RV environment. UL listed for RVs and Unconditioned Areas.Specifications:
Size: 6-3/8 in. W x 2-7/8 in. H x 1 in. D
1-year limited warranty
Flush mount
12-Volt
Color: White
Specifications:
Voltage - Input Range (Volts): 12V
Box Dimensions: 2"H x 8"W x 11"L WT: 0.45 lbs
UPC: 715456404301
Combo Carbon Monoxide Propane Alarm Surface Mount - BlackHave a safe TRIP!Test and inspect the Propane and CO alarms installed in your RV every week and replace malfunctioning alarms.Replace all Propane and CO alarms that are 5 years old or older.Install alarms listed for RV use.Prevent accidents by teaching family and friends about the operation of the alarms. Never ignore a sounding alarm.Features:
Double-duty alarm - Detects both gas leaks and CO gas simultaneously
Reliable - 12V power means no missing or dead batteries to replace
Durable - Built for the extreme RV environment
Approved - Meets RVIA/NFPA requirements
End of Life Signal
Specifications:
Voltage - Input Range (Volts): 12v
Generator Shutdown: No
Fume Type: Carbon Monoxide
Box Dimensions: 2"H x 8"W x 10"L WT: 0.45 lbs
UPC: 715456357461
Gasoline Fume Detector w/Blower Control - Black Bezel - 12VThe Single Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Complete system includes Blower Control Relay, easy installation and precise monitoring. Features:
Simple Installation
Audible and visual alarm to indicate LEL (Lower Explosive Level) presence
Monitors one (1) single area
Automatically activates bilge blower
Technical Specifications:
Operating Temperature: -40° to 185°F (-40° to 85°C)
Current Draw Nominal - 55mA
Current Draw Maximum - 95mA
Operating Voltage - 9 to 30V DC
Alarm Horn - 68 dB
Display Style - Round with Chrome Bezel
Display Dimensions - 2-3/16" (5.6 cm) round
Cutout Dimension - 2-1/16" (5.2 cm) round hole
In the Box:
Fume Detector
Fuel sensors x one (1)
20' Extension Cable x one (1)
Blower Relay x one (1)
Instruction manual
*Sold as an Individual Specifications:
Blower Relay: Yes
Fume Type: Gasoline
Generator Shutdown: No
Sensors Included: 1
Voltage - Input Range (Volts): 9 to 30
Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs
UPC: 619749202523
Owner's Manual (pdf)Brochure (pdf)
Engine Shutdown - 5 Circuit with 20A Relays - Round Display If a fire breaks out aboard a diesel-powered vessel, the engine(s) must be shut down prior to or during the discharge of a suppression system to effectively extinguish the fire. Continued engine operation may remove the agent, lowering the concentration required to effectively extinguish the fire, making an Engine Shutdown System necessary. Consisting of a Shutdown Control Module and Helm Display Unit with an Override Button the Fireboy Engine Shutdown System is an effective means to automatically shut down engines, generators, and blower systems in the event of a fire.Technical Specifications:
Operating Voltage - 9 to 38 VDC
Maximum Current Draw - 310mA @ 12 VDC
Operating Temperature - 22°F (-6°C) to 158°F (70°C)
Circuits - Five (5) with 20 Amp relays
*Sold as an Individual Owner's Manual (pdf)
62 Series Carbon Monoxide Alarm - 12V - 62-541-Marine Surface Mount - WhiteMini Carbon Monoxide Alarm with a compact space saving design that replaces your CO alarms that are over 5 years old!Features:
Space Saving. Compact design for boats
Designed for the harsh marine environment
No False Alarms due to new boat smell, outgassing or non-hazardous levels of hydrocarbon gases encountered while boating
Advanced Technology - Alarm Mute button silences alarm while boat is ventilated
Rapid recovery sensor resets when silenced or reactivates alarm if dangerous levels of CO remain
Reliable - 12 Volt power means no missing or dead batteries to replace
Memory Scan™ - Retains the CO level that activated the alarm. After ventilation, it is impossible to know what the CO level was unless your detector has memory
Micro Current Technology - Saves precious battery power in a boat
62-541-R-Marine and 62-542-R-Marine include normally closed relay
Use to turn on exhaust fans, remote horns/lights/signals or connect to alarms systems
Listed to UL 2034 Marine Use and CSA 6.19-01
Specifications:
Fume Type: Carbon Monoxide
Generator Shutdown: No
Voltage - Input Range (Volts): 12v
Box Dimensions: 3"H x 8"W x 10"L WT: 0.4 lbs
UPC: 715456625416
Quick Guide (pdf)Owner's Manual (pdf)
62 Series Carbon Monoxide Alarm - 12V - 62-542-Marine - Flush Mount - WhiteMini Carbon Monoxide Alarm with a compact space saving design that replaces your CO alarms that are over 5 years old!Features:
Space Saving
Compact design for boats
Designed for the harsh marine environment
No False Alarms due to new boat smell, outgassing or non-hazardous levels of hydrocarbon gases encountered while boating
Advanced Technology - Alarm Mute button silences alarm while boat is ventilated
Rapid recovery sensor resets when silenced or reactivates alarm if dangerous levels of CO remain
Reliable - 12 Volt power means no missing or dead batteries to replace
Memory Scan™ - Retains the CO level that activated the alarm. After ventilation, it is impossible to know what the CO level was unless your detector has memory
Micro Current Technology - Saves precious battery power in a boat
62-541-R-Marine and 62-542-R-Marine include normally closed relay
Use to turn on exhaust fans, remote horns/lights/signals or connect to alarms systems
Listed to UL 2034 Marine Use and CSA 6.19-01
Specifications:
Fume Type: Carbon Monoxide
Generator Shutdown: No
Voltage - Input Range (Volts): 12v
Box Dimensions: 3"H x 8"W x 10"L WT: 0.4 lbs
UPC: 715456625423
Quick Guide (pdf)Owner's Manual (pdf)
Optical Smoke Detector with BaseOptical smoke detectors have consistently been recognized as suitable detectors for general use. They are regarded as particularly suitable for smoldering fires and escape routes. This smoke detector is also designed to significantly reduce the incidence of false alarms through over-sensitivity to transient phenomena.Features:
Recommended for use as general-purpose smoke detectors for early warning of fires in most areas
Works well in black as well as in white smoke
Compensation for slow changes in sensitivity
Extra confirmation of smoke before an alarm signal is given
Specifications:
Sampling Frequency: Once every four seconds
Operating Voltage: 8.5 V dc to 33 V dc
Supply Wiring: Two wire supply, polarity sensitive
Power-up Time: < 20 seconds
Minimum ‘Detector Active’ Voltage: 6 V
Minimum Holding Current: 8 mA
Minimum Voltage to Light Alarm LED: 5 V
Alarm Reset Time: One second
Alarm Indicator: Integral indicator with 360º visibility
Operating & Storage Temperature: -40ºC to +70ºC
Humidity (no condensation or icing): 0% to 98% RH
Operation:
Optical Smoke Detectors work on the well-established light scatter principle
The remarkable optical design of this Smoke Detector enables it to respond to a wide spectrum of fires
The sensing chamber contains an optical sensor that measures back-scattered light as well as the more usual forward-scattered light
The detector is calibrated so that it is highly reliable in detecting fires but is much less likely to generate false alarms
The stability of the detector-high reliability, low false alarm rate is further increased by the use of algorithms to decide when the detector should change to the alarm state
Removes the likelihood of a detector producing an alarm as a result of smoke from smoking materials or another non-fire source
Specifications:
Fume Type: Smoke
Box Dimensions: 2"H x 5"W x 7"L WT: 0.35 lbs
UPC: 619749321095
Gasoline Fume Detector - Chrome Bezel - 12/24VThe Single Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Features:
Simple Installation
Audible and visual alarm to indicate LEL (Lower Explosive Level) presence
Monitors one (1) single area
Technical Specifications:
Operating Temperature: -40° to 185°F (-40° to 85°C)
Current Draw Nominal - 55mA
Current Draw Maximum - 95mA
Operating Voltage - 9 to 30V DC
Alarm Horn - 68 dB
Display Style - Round with Chrome Bezel
Display Dimensions - 2-3/16" (5.6 cm) round
Cutout Dimension - 2-1/16" (5.2 cm) round hole
In the Box:
Fume Detector
Fuel sensors x one (1)
20' Extension Cable x one (1)
Instruction manual
*Sold as an Individual Specifications:
Blower Relay: No
Fume Type: Gasoline
Generator Shutdown: No
Sensors Included: 1
Voltage - Input Range (Volts): 9 to 30
Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs
UPC: 619749202530
Owner's Manual (pdf)Brochure (pdf)
Gasoline Fume Detector with Dual Channel and Blower Control - 12/24VThe Dual Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Complete system includes Blower Control Relay, easy installation and precise monitoring. Features:
Simple Installation
Audible and visual alarm to indicate LEL (Lower Explosive Level) presence
Monitors two (2) separate areas simultaneously
Automatically activates bilge blower
Technical Specifications:
Operating Temperature: -40° to 185°F (-40° to 85°C)
Current Draw Nominal - 55mA
Current Draw Maximum - 150mA
Operating Voltage - 9 to 30V DC
Alarm Horn - 68 dB
Display Style - Square with Black Bezel
Display Dimensions - 2-5/8" x 2-5/8" (6.7 x 6.7 cm)
Cutout Dimension - 2-1/8" (5.4 cm) round hole
In the Box:
Fume Detector
Fuel sensors x two (2)
20' Extension Cable x two (2)
Blower Relay x one (1)
Instruction manual
*Sold as an Individual Specifications:
Blower Relay: Yes
Fume Type: Gasoline
Generator Shutdown: No
Sensors Included: 2
Voltage - Input Range (Volts): 9-30v
Box Dimensions: 4"H x 4"W x 8"L WT: 1.6 lbs
UPC: 619749202561
Owner's Manual (pdf)Brochure (pdf)
62 Series Carbon Monoxide Alarm w/Relay - 12V - 62-541-Marine-RLY-NC - Surface Mount - WhiteMini Carbon Monoxide Alarm with a compact space saving design that replaces your CO alarms that are over 5 years old! The 62-541-Marine-RLY-NC includes a normally closed relay. Used to turn on exhaust fans, remotes, horns, lights, signals or connect to alarm systems.Features:
Space Saving. Compact design for boats
Designed for the harsh marine environment
No False Alarms due to new boat smell, outgassing or non-hazardous levels of hydrocarbon gases encountered while boating
Advanced Technology - Alarm Mute button silences alarm while boat is ventilated
Rapid recovery sensor resets when silenced or reactivates alarm if dangerous levels of CO remain
Reliable - 12 Volt power means no missing or dead batteries to replace
Memory Scan™- Retains the CO level that activated the alarm. After ventilation, it is impossible to know what the CO level was unless your detector has memory
Micro Current Technology - Saves precious battery power in a boat62-541-R-Marine and 62-542-R-Marine include normally closed relay
Use to turn on exhaust fans, remote horns/lights/signals or connect to alarms systems
Listed to UL 2034 Marine Use and CSA 6.19-01
Specifications:
Fume Type: Carbon Monoxide
Generator Shutdown: No
Voltage - Input Range (Volts): 12v
Box Dimensions: 2"H x 8"W x 10"L WT: 0.4 lbs
UPC: 715456625539
Quick Guide (pdf)Owner's Manual (pdf)