PRO NMEA 0183 Multiplexer/NMEA 2000 GatewayInterconnectivity, reimagined!The PRO-NDC-1E2K is much more than an NMEA 0183 Multiplexer…Rugged, Robust, Type Approved Multiplexer with built-in NMEA 2000 connectivity, high-speed Ethernet streaming of data, flexible configuration, auto-switching and sentence level filtering.Managing and routing your NMEA data is straight forward, hassle free using the PRO-NDC-1E2KFeatures:
Auto-switching between inputs to allow for a primary, secondary, tertiary priority input.
Configurable baud rates to allow 38400 and 4800 baud devices to operate through the same multiplexer.
Sentence filtering to block unwanted sentences from specific outputs helps to limit bandwidth consumption.
Easy to configure using the web based UI, no need to manually enter and edit strings of text.
RINA type approved device means the multiplexer is fit for leisure, commercial and class / type installations.
Multiple LED’s allow for ‘quick glance’ diagnostics to ensure everything is operating correctly.
Certified NMEA 2000 device connectivity allows for conversion and output of data onto NMEA 2000 network.
Bi-directional conversion to and from N2K Network allows for seamless integration between legacy and new equipment.
NMEA 0183 data streaming over Ethernet enables connectivity to existing Ethernet devices and systems.
NMEA 2000 data streaming over Ethernet.
5 OPTO-Isolated NMEA 0183 inputs and 2 ISO-Drive NMEA 0183 outputs provide protection for all connected instruments.
Type-approved (RINA).
NMEA 0183 Ethernet streaming
NMEA 2000 Ethernet streaming
NMEA 2000 output via M12
5x Configurable Opto-isolated NMEA 0183 inputs.
2x Configurable ISO-Drive isolated NMEA 0183 outputs.
1x Bi-directional, configurable, isolated serial port.
Automatic baud rate matching on inputs.
Advanced data filtering / routing.
Free firmware updates making the device future-proof.
Diagnostic LEDs on all inputs and outputs.
Bi-colour status LED.
Panel mountable.
Stainless Steel housing for added durability
Quick and easy to install
Configuration using standard web browser, no PC operating system compatibility issues
Advanced features solve NMEA 0183 data routing problems
Fully isolated with ISO-Drive technology for peace of mind
Easy firmware updates make the device future-proof
Type Approved (RINA)
Technical Specifications:Power Supply
Input supply voltage - 9 to 35 V DC
Input supply current - 150mA max @ 12V DC (all outputs @ full drive into 100 ohm loads)
Input protection - Continuous reverse polarity, transient overvoltage and ESD protection
Power indicator - LED, Blue – indicates unit is functioning correctly
Input Supply connector - Pluggable 2-way screw terminal, 5.08mm pitch (12 to 30 AWG)
NMEA 0183 Port – Listener & Talker
Number of Listener / Input Ports - 5 isolated NMEA 0183 Listeners
Number of Talker / Output Ports - 2 isolated NMEA 0183 Talkers
Compatibility - Fully NMEA 0183, RS422 & RS232 compatible. RS485 Listener compatible
Speed / baud rate - 4800 to 38400 bps
Talker Output Voltage Drive - >= 2.2V (differential) into 100 ohm
Talker Output Current Drive - 20 mA maximum per output
Talker Output Protection - Short circuit and ESD
Talker Data Indicator - LED, Orange (Flashes with data rate)
Listener Input Voltage Tolerance - -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
Listener Input Protection - Current limited, overdrive protection to 40 VDC and ESD protection
Listener Data Indicator - LED, Green (Flashes with data rate)
Connectors - Pluggable 2/3 way screw terminals, 5.08mm pitch (12 to 30 AWG)
Serial Port
Compatibility - RS422 & RS232 compatible. RS485 Listener compatible
Speed / baud rate - 115200 bps
Output voltage drive - >= 2.1V (differential) into 100 ohm
Output current drive - 20 mA max.
Output protection - Short circuit and ESD
Input voltage tolerance - -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
Input protection - Current limited, overdrive protection to 40 VDC and ESD protection
Data Indicators - LED’s: Green = Receive, Orange = Transmit
Connectors - Pluggable 3-way screw terminals, 5.08mm pitch (12 to 30 AWG)
Ethernet Port
Host interface - 10/100BaseT, automatic polarity detection
Supported protocols - TCP/IP for configuration and firmware updating, TCP/IP and UDP for NMEA 0183 comms
Connector - RJ45
Indicators - Green – Link, Yellow – 100 Mbps
NMEA 2000 Port
Compatibility - NMEA 2000 Certification Pending
Speed / baud rate - 250 kbps
Connectivity - M12 male (A-coded) connector
Isolation
NMEA 0183 Listener - Uses IsoDriveTM, Hi-Pot tested to 1000V
NMEA 0183 Talker - Uses IsoDriveTM, Hi-Pot tested to 1000V
Serial Port - Uses IsoDriveTM, Hi-Pot tested to 1000V
Ethernet Port - 2kv for 60s
NMEA 2000 Port - OPTO-Isolated, Hi-Pot tested to 1000V
Mechanical
Housing Material - 316 Stainless Steel
Dimensions - 139mm (W) x 98mm (H) x 26mm (D)
Weight - 360g
Mounting - Bulkhead mount or DIN rail mount (DIN kit 1)
Approvals and Certifications
EMC - IEC 60945:2002-08, DNVGL-CG-0339:2019 & IACS UR E10 Rev7
Compass Safe Distance - 300mm
Type Approval Certificate - RINA
Operating Temperature - -25 to +70°C
Storage Temperature - -40 to +85°C
Relative Humidity (RH) - 95% @ 55°C
Environmental Protection - IP40
Guarantee - 5 Years when registered
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Specifications:
Data Interface: NMEA 0183
Box Dimensions: 2"H x 6"W x 10"L WT: 1.05 lbs
UPC: 5060998710751
Quick Guide (pdf)Owner's Manual (pdf)Brochure (pdf)
0183 to N2K Gateway with PC Interface, USB ConnectionIntelligent Gateway technology enables PC interfacing and NMEA data conversion…The NGX-1 is an intelligent multi-function gateway, combining the power of our two previous generation products (NGT-1 and NGW-1) into one, cost effective, flexible product.Configure the NGX-1 to operate as an NMEA 2000 <–> PC interface, or as a bi-directional NMEA 0183 <–> NMEA 2000 conversion gateway.Features:
View all NMEA 2000 network data on Actisense NMEA Reader. The device supports every available PGN in the NMEA 2000 standard.
View converted NMEA 0183 data on Actisense NMEA Reader. The device sports the largest conversion library of any gateway.
Easily interface with a wide range of PC applications via the NGX-1, such as TimeZero (NMEA 2000) and OpenCPN (NMEA 0183).
Configure the Actisense EMU-1, NGW-1 and NGX-1 via Actisense Toolkit using an NGX-1.
Connect legacy NMEA 0183 instruments together with new NMEA 2000 networks, greatly reducing upgrade costs.
Vital NMEA 2000 diagnostic tool
Fully isolated to prevent dangerous ground loops
Up to 230,400 baud data transfer rate
Advanced configuration using Actisense Toolkit allows Tx / Rx lists and Tx rates to be set
Supports Fast Heading at 10Hz
Multiple diagnostic LEDs
Allows all major PC Chartplotter applications to interface with the NMEA 2000 bus
Provides a rule-enforcing firewall between the PC and the NMEA 2000 bus
Powerful diagnosis of the NMEA 2000 network using the FREE NMEA Reader software provided
Configure and flash-update Actisense products on the bus
Upgrade NMEA 0183 equipment to NMEA 2000
Allow NMEA 0183 devices to receive vital NMEA 2000 data
Use the NMEA 2000 bus to multiplex several NMEA 0183 signals together
Reliable, renowned bi-directional conversion engine
Supports a wide range of conversions including AIS
Easily configurable using Actisense Toolkit
Technical SpecificationsPower Supply
Supply Voltage (NMEA 2000 Port) - 9 to 30V DC
Supply Current (NMEA 2000 Port) - 62mA @ 9V DC
Load Equivalent Number (LEN) - 2
NMEA 2000 Port
Speed / Baud Rate - 250kbps
Connectivity - M12 Male (A coded)
USB Port
Compatibility - USB 1.1, 2.0 and 3.0
Speed / Baud Rate - 4800 to 230400 Baud
Connectivity - Male type A plug moulded onto cable
Cable Length - 1.8m
Isolation
NMEA 2000 Port to ISO Port - Uses IsoDriveTM, Hi-Pot tested to 1000V
NMEA 2000 Port to USB Port - Galvanic Isolation, Hi-Pot tested to 1000V
Mechanical
Housing Material Body - Flame retardant Polycarbonate
Housing Material End Caps - Flame retardant PBT
Weight - 113g
Approvals and Certifications
NMEA 2000 - NMEA 2000 Certified
NMEA 0183 - Meets IEC 61162-1 & 61162-2 Requirements
RoHS and REACH - Compliant
Module Certification - KCC / BQB / IC / Wi-Fi / NCC / MIC / FCC DSS / FCC DTS / SRRC / CE, EN 60945:2002 Edition 4 (section 9.3), EN 301 489-1 V2.2.3, EN 301 489-17 V3.2.4
EMC - EN 300 328 V2.2.2 Radiated Spurious Emissions, FCC Part 15b, ICES-003 Iss 7
Environmental Protection IP67
Operating Temperature -25°C to +70°C
Storage Temperature -30°C to +70°C
Recommended Humidity 0 to 93% RH @ 40°C
Guarantee 3 years, extended to 5 years upon registration
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Specifications:
Data Interface: NMEA 0183
Box Dimensions: 2"H x 6"W x 6"L WT: 0.5 lbs
UPC: 5060998710560
Quick Guide (pdf)Owner's Manual (pdf)Brochure (pdf)
N2K Micro 4 Way T-PieceThe 4 Way T-Piece from Actisense saves you time, space and money on your NMEA 2000® installation.The Actisense 4 Way T-Piece is for use where multiple drops or ‘ports’ are required from the NMEA 2000 backbone. It’s as quick and easy to install as a single T-Piece, uses less space than two individual T-pieces and costs less than four.The Actisense range of NMEA 2000 connectors and cables has been designed using our specialist interconnect and NMEA knowledge.Features:
NMEA 2000 Approved
RoHS Compliant
Technical Specifications:Electrical
Rated Current - 4A
Rated Voltage - 60V DC
Mechanical
Male Contact - Brass, gold plated
Female Contact - Phosphor bronze, gold plated
Contact Carrier - PA66 (30% Glass filled), black
Contact Polarization - Standard M12 -“A”- polarization
Mating Thread - M12
Screw Cap - Brass, nickel plated
O-Ring Seal - Rubber, Black
Housing - TPU, flame retardant to UL94V-0, Halogen Free
Internal Housing Shield - Copper Foil
Weight - 105g
Approvals and Certifications
Protection - IP67 (when mated)
Operating Temperature - -20°C to +70°C
Storage Temperature - -40°C to +85°C
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Specifications:
Data Interface: NMEA 2000
NMEA 2000 Connectors: Tee Connectors
Box Dimensions: 2"H x 3"W x 5"L WT: 0.25 lbs
UPC: 5060998710010
Brochure (pdf)
Micro Bulk Cable Single Piece - 100M SpoolMicro bulk cable is primarily used as drop cable, but it can also be used as the trunk line depending on network power requirements. Bulk cable with field-attachable connectors allows for maximum flexibility as cables can be made on the job to exact lengths.Features:
Single Piece
100M Spool Length
Trunk of drop cable for use with Micro Connectors
Used with field attachable connectors to build exact length cables at the job site
Specifications:
Data Interface: NMEA 2000
Cable Length (Meters): 100m
Box Dimensions: 12"H x 12"W x 12"L WT: 17.6 lbs
UPC: 087380400309
NMEA 2000 Four Way Tee ConnectorAncor's NMEA 2000 Approved Tee Connectors offer connection between NMEA 2000 drop cables and backbone cables. The yellow couplers connect to the corresponding Ancor tees and backbone cables, creating a simplified, color coded network installation. The connectors are offered in four configurations for maximum installation flexibility. The two way and four way tee connectors allow for multiple drop cables to be connected without additional backbone cable.Features:
Color coded for easy installation and component identification
NMEA 2000 Approved, 100 percent universal and compatible with other manufacturers' products
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Data Interface: NMEA 2000
NMEA 2000 Connectors: Tee Connectors
Box Dimensions: 2"H x 4"W x 7"L WT: 0.2 lbs
UPC: 091887982299
Brochure (pdf)
NMEA 2000 Female TerminatorAncor's NMEA 2000 Approved Terminators allow for proper termination of an NMEA 2000 network. The yellow couplers connect to the corresponding Ancor tees, creating a simplified, color coded network installation. One male and one female terminator is required for each NMEA 2000 network.Features:
Color coded for easy installation and component identification
NMEA 2000 Approved, 100 percent universal and compatible with other manufacturers' products
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Connection Gender: Female
Data Interface: NMEA 2000
NMEA 2000 Connectors: Terminators
Box Dimensions: 1"H x 3"W x 5"L WT: 0.5 lbs
UPC: 091887982305
Brochure (pdf)
NMEA 2000 Male TerminatorAncor's NMEA 2000 Approved Terminators allow for proper termination of an NMEA 2000 network. The yellow couplers connect to the corresponding Ancor tees, creating a simplified, color coded network installation. One male and one female terminator is required for each NMEA 2000 network.Features:
Color coded for easy installation and component identification
NMEA 2000 Approved, 100 percent universal and compatible with other manufacturers' products
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Connection Gender: Male
Data Interface: NMEA 2000
NMEA 2000 Connectors: Terminators
Box Dimensions: 2"H x 3"W x 5"L WT: 0.2 lbs
UPC: 091887982312
Brochure (pdf)
Pressure Transducer 0 to 3 PSI - for the FPM100 Fluid Pressure MonitorWARNING: This product can expose you to chemicals including NICKEL (METALLIC) which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov. Owner's Manual (pdf)
FI5002 NMEA2000 Junction BoxThe FI5002 is an NMEA2000 Certified, 6-Port Junction Box for use with for use with any NMEA2000 network. The FI5002 features 2 NMEA2000 backbone ports, as well as 6 NMEA2000 ports. It will support up to 2A or 40 (LEN) on a 12VDC network.The FI5002 will also support 24VDC networks. Features
2 NMEA2000 backbone ports
6 NMEA2000 ports
Less than 2A power requirement on a 12VDC system
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns. Specifications:
Data Interface: NMEA 2000
Box Dimensions: 2"H x 7"W x 9"L WT: 1.2 lbs
UPC: 611679314697
Quick Guide (pdf)
NMEA 2000 Field Serviceable Connector - MaleFor termination of bare NMEA cable. Securely terminate bulk cable or replace a broken end.WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Connection Gender: Male
Data Interface: NMEA 2000
NMEA 2000 Connectors: Field Connectors
Box Dimensions: 1"H x 3"W x 5"L WT: 0.05 lbs
UPC: 091887982350
Fuel Flow MonitorPart #: FFM100-01Maretron's FFM100 provides precision fuel flow information to help optimize fuel consumption, which can save thousands of dollars in fuel operating cost. The FFM100 uses state-of-the-art, positive displacement metering technology for unprecedented accuracy. In fact, the accuracy of the FFM100 is nearly that of commercial vessel systems costing tens of thousands of dollars, yet the FFM100 cost less than existing recreational systems found on the market today. Additional benefits of the positive displacement metering technology are the elimination of flow conditioning components such as straighteners and pulsation dampers. Other flow meter technologies require flow conditioning components that increase system and installation cost. The FFM100 also uses true temperature compensation with embedded temperature sensors within the meters. The returning fuel is generally hotter than the supply fuel and if not properly compensated, inaccuracies as much as 5% can occur in computing the engine's fuel consumption. The FFM100 also detects momentary reverse flow in the fuel lines due to fluctuating pressure caused by the injection pump. Less accurate systems count the reverse fuel flow as part of the consumed fuel where the FFM100 properly accounts for momentary reverse flow.Lastly, the FFM100 can be used for fluid types other than fuel (e.g., water, oil, etc.) by ordering the appropriate flow sender.The FPM100 is NMEA 2000® certified so you can view any and all information anywhere on the vessel using a compatible NMEA 2000® display. The FFM100 is a key component of Maretron's N2KView® vessel monitoring and control system. Features:
FFM100 converts a variety of flow senders (e.g., fuel, water, etc.) to NMEA 2000® Network Data
All flow senders ordered separately depending on application (i.e., single fuel flow sender for gas engine, dual fuel flow senders for diesel engine, water flow sender for sea water, etc.)
Fuel flow senders facilitates fuel consumption optimization for reduced fuel operating cost
Fuel flow senders use positive displacement metering technology for superior accuracy over other measurement technology such as turbine meters
Fuel flow senders do not require costly fuel conditioning components like flow straighteners and pulse dampers
Fuel flow senders implement true temperature compensation with precision built-in thermistors for increased accuracy
Fuel flow senders automatically detect reverse flow due to fluctuating pressure difference from injection pumps
Fuel flow senders pass particle sizes up to 70 micrometers (diesel fuel filters normally filter down to 2 micrometers to prevent clogging injectors)
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Quick Guide (pdf)Owner's Manual (pdf)
NMEA 2000 field installable connector - femaleWARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov. Specifications:
Connection Gender: Female
Data Interface: NMEA 2000
NMEA 2000 Connectors: Field Connectors
Box Dimensions: 1"H x 1"W x 1"L WT: 0.1 lbs
UPC: 753759078379